| Filtration Area | 0.11 m² |
|---|---|
| MWCO | 100 kDa |
| Screen Type | Standard Coarse Screen |
| Filter Format | Consieve™ UET TFF Cassettes |
|---|---|
| Scale | Lab Scale, Process Development |
| Filtration Area | 0.01 m²/ 0.02 m²/ 0.11 m² |
| Flow Channel | A Type - Tight Screen 0 Type - Standard Coarse Screen V Type - Suspended Screen |
| MWCO | 1/ 3/ 5/ 8/ 10/ 30/ 50/ 100/ 300/ 500/ 1000 kDa |
| Membrane Material | Polyethersulfone (PES) |
|---|---|
| Screen Material | Polypropylene (PP) |
| Gasket Material | Silicone |
| Encapsulant Material | Silicone |
| pH Stability | 1.0-14.0 |
|---|---|
| Max. Operating Pressure | 4 bar |
| Max. Operating Temperature | 50 °C |
| Compliance | USP <788> Particulate Matter USP <87> Cytotoxicity USP <88> Biological Reactivity FDA Indirect Food Additives, 21 CFR 177-182 ADCF Materials |
|---|
Answer:100 kDa MWCO and 0.11 m² effective filtration area.
Answer:No. This variant has 0.11 m² filtration area.
Answer:Yes, with compatible validated cleaning and integrity checks; it is supplied non-sterile.
The Cobetter Consieve UET Lab PES TFF Cassette is a reusable tangential-flow ultrafiltration device with a 100 kDa nominal molecular-weight cutoff and an effective filtration area of 0.11 m². The modified polyethersulfone membrane provides a hydrophilic, low-protein-binding surface for process development involving selected high-molecular-weight proteins, protein complexes and other large biomolecular products. The 100 kDa cutoff must be chosen against the actual product size and desired transmission of smaller components; it is not a fixed pore-size rating in micrometers. Use a compatible laboratory cassette holder that accommodates the 0.11 m² format, along with suitable flow-rate and pressure monitoring. The cassette is reusable after validated cleaning and is supplied individually in non-sterile packaging. Before first use, flush the protective storage solution from the membrane and establish an appropriate baseline water flux. A laboratory-format cassette is not physically interchangeable with the larger 0.5 m² pilot cassette without checking holder geometry.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Bacterial Endotoxin | Endotoxin Limit of WFI System<0.25 EU/mL with the Limulus Amebocyte Lysate (LAL), USP <85> |
|---|
| Reusable | Yes |
|---|---|
| Pre-use Treatment | Shipped wet in an aqueous solution containing 0.1M~0.2M NaOH and 20% glycerin. Flush the cassette well with water prior to use. |
| Sterility | Non-sterile |
| Pack Size | Pack of 1 |
|---|---|
| Packaging | Individually packed in a double PE bag |