Description
Broad application range: suitable for ^3 H, ^125 I, ^14 C, ^32 P, ^33 P, ^35 S and more Storage phosphor screens capture latent images produced by ionizing radiation, including X-rays, β particles emitted from radioisotopes commonly used in research (e.g. ^3 H, ^14 C, ^32 P, ^33 P, and ^35 S), and γ rays (e.g. from ^125 I, ^131 I, and ^99m TC). Upon laser-induced stimulation, light is emitted from the storage phosphor screen in proportion to the amount of radioactivity in the sample. The resulting digital image allows for quantitation of subtle signal intensity differences over a wide dynamic range using a storage phosphorimager system (e.g. Typhoon, Storm, or PhosphorImager) together with analysis software such as ImageQuant. Typically, 50% to 90% less exposure time is required compared with an equivalent exposure to conventional autoradiography film. Publication quality images are often obtained in a single exposure. How storage phosphor screens work A storage phosphor screen is a film-like sensor designed to trap and store radiation energy in a stable state. BAS Storage Phosphor Screens contain a photostimulable layer of phosphor particles (BaFBr) sandwiched between a protective layer and a support film coated with trace amounts of bivalent europium (Eu2+) as a luminescence center. Particles in the phosphor layer stably absorb ionizing radiation, which is later released as blue-violet light (400nm) upon laser stimulation in a storage phosphorimager system. Storage phosphor screens are reusable* and are not degraded by repeated exposure to laboratory levels of radioactivity. To reuse, simply expose a screen to the extra-bright light of an ImageEraser light box. Product selection Three types of BAS Storage Phosphor Screen are available to suit differing applications: Multipurpose Standard (MS) screens: Suitable for use with ionizing radiation from isotopes such as ^14 C, ^125 I, ^131 I, ^32 P, ^35 S, and ^99m Tc. This is the screen of choice for ^32 P Northerns and Southerns and ^125 I Western blots and gels. Super Resolution (SR) screens: Provide higher resolution where a pixel resolution of 50 μm is required; compatible with storage phosphor imaging systems such as Amersham™ Typhoon™ , Typhoon FLA 7000, Typhoon FLA 7000 IP, and Typhoon FLA 9500 . Tritium (TR) screens: Highly sensitive screens constructed without a protective layer, for detection of the weak energy of ^3 H emissions. Optimal results are obtained when the tritium signal is on the surface of the sample and available to penetrate the screen. Since these screens lack of protective layer, TR screens are for single-use. *TR screens are recommended for single use only.