Hach, 77065-100, Non-oil filled with connector, 0 to 10 ft range, 100 ft cable
Catalog Number: 77065-100
Send an RFQ.
Category
| Operating Unit | Typical Minimum Operating Depth: 2 cm |
|---|
| Accuracy 2 | VELOCITY MEASUREMENT: ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific. |
|---|---|
| Accuracy 3 | LEVEL MEASUREMENT: ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC) ±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF); ±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF) |
| Accuracy 4 | Velocity-Induced Depth Error Compensated based on flow velocity |
| Allowable Level | Standard: 10.5 m (34.5 ft) Extended: 31.5 m (103.5 ft) |
| Cable | Urethane sensor cable with air vent |
| Cable Length | 100 ft |
| Compatible Instruments | 920, 930, 930T, 950, 900 Max Samplers, and AV9000 Interface Analyzer Module |
| Dimensions (H x W x D) | 23 mm x 38 mm x 135 mm |
| Level Accuracy | ±0.16% full scale ±1.5% of reading at constant temp (±2.5ºC) ±0.20% full scale ±1.75% of reading from 0 to 30ºC (32 to 86ºF) ±0.25% full scale ±2.1% of reading from 0 to 70ºC (32 to 158ºF) |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Level Measurement Method |
|---|
| Differential pressure transducer with stainless steel diaphragm and atmospheric pressure reference |
| Level Range | 0 to 10 ft range |
|---|
| Material | Noryl® outer shell with epoxy potting within |
|---|
| Measurement method | LEVEL Pressure transducer with stainless steel diaphragm |
|---|
| Oil or Non-Oil Filled | Non-oil filled with connector |
|---|
| Operating Temperature Range | 0 - 70 °C |
|---|
| Recommended Range | -1.52 to 6.10 m/s (-5 to 20 ft/sec) |
|---|
| Special Features | Non-oil Filled, 100 ft cable |
|---|
| Typical Minimum Operating Depth | 2 cm (0.8cm) |
|---|
| Velocity Accuracy | ±2% of reading or 0.05 fps** **Uniform velocity profile, known salinity, positive flow. Field performance is site specific. |
|---|
| Velocity Measurement Method | Doppler ultrasonic; twin 1 MHz piezoelectric crystals |
|---|
| Velocity-Induced Depth Error | Compensated based on flow velocity |
|---|
| Warranty | 12 months |
|---|