Hach, DGK510KK-W-IMP, Kit: Dual-channel Orbisphere 510 controller, 2x K1100 LDO sensors (0-2000 ppb), 2x ¼" flow chamber, wall mount
Catalog Number: DGK510KK-W-IMP
Send an RFQ.
Category
| Accuracy | ± 0.8 ppb or 2 % whichever is greater |
|---|---|
| Ambient Temperature | -5 - 50 °C (23 - 122°F) |
| Analog Outputs | 3 Smart 0/4 to 20 mA (500 Ohms) programmable as linear or tri-linear, configurable to send diagnostics or alarm informations. |
| Application | Power |
| Calibration | Single point zero calibration with standard 99.999% nitrogen (quality 5.0) or equivalent oxygen free gas |
| Certifications | 2004/108/EC - EN 61326-1 |
| Communication Capabilities | 3 x 0/4-20 mA; RS485; Ethernet |
| Controller | Wall |
| Controller Options | 510 Multi-Channel Controller |
| Display Resolution | 0.1 ppb |
| Lower Limit of Detection (LOD) | 0.6 ppb |
| Mounting | Two 1/4" flow chambers |
| Parameter | Oxygen |
| Power Requirements (Voltage) | 100 - 230 VAC |
| Range | 0 - 2000 ppb dissolved O₂ (DO) |
| Relays | Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC). |
| Repeatability | ± 0.4 ppb or 1 % whichever is greater |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Reproducibility | ± 0.8 ppb or 2 % whichever is greater |
|---|
| Response Time | (90%) <10 s (gas phase); <30 s (liquid phase) |
|---|
| Sample Flow Rate | 50 - 300 mL/min |
|---|
| Sample Pressure | 1 - 20 bar absolute (14.5 - 290 psi) |
|---|
| Sample Temperature | -5 - 50°C (23 - 122°F) |
|---|
| Sensors | Two K1100 LDO |
|---|
| Storage Conditions | -5 °C - 100 °C |
|---|
| Temperature Range | Accurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F) |
|---|
| Warranty | 12 months |
|---|
| Weight Sensor | 0.6 |
|---|
| What's included? | 1x Orbisphere controller 510KK0/W1C00000, 2x K1100-S00 sensor (low level), 2x ¼" flow chamber 32001.011, 2x 32510.10 sensor cable (10 m) to connect M/K-type sensor with Orbisphere 510 instruments |
|---|