Hach, EZ4004.XXXXXXXX, EZ4004 Total Alkalinity Analyzer
Catalog Number: EZ4004.XXXXXXXX
Send an RFQ.
Category
| Alarm | 1x malfunctioning, 4x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
|---|---|
| Ambient Temperature | 10 - 30 °C ± 4 °C deviation (50 - 86 °F ± 7.2 °F deviation) at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option) |
| Calibration | Automatic, 2-point; frequency freely programmable |
| Certifications | CE compliant / UL certified |
| Cycle Time | 10 - 15 minutes |
| Demineralized Water | For rinsing / dilution |
| Digital Outputs | Optional: Modbus (TCP/IP, RS485) |
| Dimensions (H x W x D) | 690 mm x 465 mm x 330 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
| Interferences | Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally. |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Lower Limit of Detection (LOD) | ≤ 10 mg/L |
|---|
| Material | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated |
|---|
| Measurement Method | Acid-base titration with hydrochloric acid |
|---|
| Method Name | Titrimetric |
|---|
| Number of sample streams | 1, 2, 4 or 8 |
|---|
| Parameter | Alkalinity, total |
|---|
| Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
|---|
| Precision | Better than 2% full scale range for standard test solutions |
|---|
| Protection Class | Protection class: Analyser cabinet: IP44 / Panel PC: IP65 |
|---|
| Range | 100 - 5000 mg/L CaCO 3 Optional: 10 - 500 mg/L CaCO 3 25 - 1250 mg/L CaCO 3 50 - 2500 mg/L CaCO 3 Internal dispenser dilution (max. factor 100) |
|---|
| Range | 100 - 5000 mg/L CaCO₃ |
|---|
| Reagent Requirements | Keep between 10 - 30 °C (50 - 86 °F) |
|---|
| Sample Flow Rate | 100 - 300 mL/min |
|---|
| Sample Pressure | By external overflow vessel |
|---|
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
|---|
| Sample Temperature | 10 - 30 °C (50 - 86 °F) |
|---|
| Validation | Automatic; frequency freely programmable |
|---|
| Warranty | 12 months |
|---|
| Weight | 25 kg (55 lbs.) |
|---|
| What's included? | EZ4004 Alkalinity Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x pH Electrode, Routine S7 Connection, and 1 x empty 10L Reagent Container with Fittings (for HCl Solution) |
|---|