Hach, EZ4006.XXXXXXXX, EZ4006 Chloride Analyzer
Catalog Number: EZ4006.XXXXXXXX
Send an RFQ.
Category
| Alarm | 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts |
|---|---|
| Ambient Temperature | 10 - 30 °C ± 4 °C deviation (50 - 86 °F ± 7.2 °F deviation) at 5 - 95% relative humidity (non-condensing) |
| Analog Outputs | Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option) |
| Calibration | N.A. |
| Certifications | CE compliant / UL certified |
| Cycle Time | 10 - 15 minutes |
| Demineralized Water | For rinsing / dilution |
| Digital Outputs | Optional: Modbus (TCP/IP, RS485) |
| Dimensions (H x W x D) | 690 mm x 465 mm x 330 mm |
| Drain | Atmospheric pressure, vented, min. Ø 32 mm |
| Earth Connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Instrument Air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air |
| Interferences | Bromide, sulfide, iodide ions may interfere. Ferricyanide causes high results and must be removed. Chromate and dichromate interfere and should be reduced to chromic state or removed. Ferric iron interferes if present in an amount substantially higher than the amount of chloride. Chromic ion, ferrous ion and phosphate do not interfere. Fats, oil, proteins, surfactants and tar. |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Lower Limit of Detection (LOD) | 5 mg/L |
|---|
| Material | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanized steel, powder coated |
|---|
| Measurement Method | Potentiometric titration with silver nitrate (AgNO₃), conform with standard method APHA 4500-Cl (D) |
|---|
| Method Name | Titrimetric |
|---|
| Model | EZ4006 |
|---|
| Number of sample streams | 1, 2, 4 or 8 |
|---|
| Parameter | Chloride |
|---|
| Power | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
|---|
| Power Supply | 100 - 240 VAC, 50/60 Hz |
|---|
| Precision | Better than 2% full scale range for standard test solutions |
|---|
| Protection Class | Protection class: Analyser cabinet: IP44 / Panel PC: IP65 |
|---|
| Range | 25 - 500 mg/L Cl - Optional: 5 - 50 mg/L Cl - 5 - 125 mg/L Cl - 5 - 250 mg/L Cl - Internal dispenser dilution (max. factor 100) |
|---|
| Range | 25 ‐ 500 mg/L |
|---|
| Reagent Requirements | Keep between 10 - 30 °C (50 - 86 °F) |
|---|
| Sample Flow Rate | 100 - 300 mL/min |
|---|
| Sample Pressure | By external overflow vessel |
|---|
| Sample Quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
|---|
| Sample Temperature | 10 - 30 °C (50 - 86 °F) |
|---|
| Validation | Automatic; frequency freely programmable |
|---|
| Warranty | 12 months |
|---|
| Weight | 25 kg (55 lbs.) |
|---|
| What's included? | EZ4006 Chloride Analyzer, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x mV electrode, 2 x empty 10L Reagent Containers with Fittings (for Cleaning & Buffer Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for AgNO₃ Solution) |
|---|