Hach, K110H-KTO-P-MET, Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, 6 mm flow chamber, panel mount
Catalog Number: K110H-KTO-P-MET
Send an RFQ.
Category
| Accuracy | ± 0.02 ppm or 3 % whichever is greater |
|---|---|
| Ambient Temperature | -5 - 50 °C (23 - 122°F) |
| Analog Outputs | 3 Smart 0/4 to 20 mA (500 Ohms) programmable as linear or tri-linear, configurable to send diagnostics or alarm informations. |
| Application | Power |
| Calibration | Two points at cap replacement (zero and air), one during use (air) with standard 99.9% nitrogen (quality 3.0) or equivalent oxygen free gas |
| Certifications | 2004/108/EC - EN 61326-1 |
| Communication Capabilities | 3 x 0/4-20 mA; RS485; Ethernet |
| Controller | Panel |
| Controller Options | 410 Mono-Channel Controller |
| Display Resolution | 0.1 ppb |
| Lower Limit of Detection (LOD) | 0.015 ppm |
| Mounting | 6 mm flow chamber |
| Parameter | Oxygen |
| Power Requirements (Voltage) | 100 - 230 VAC |
| Range | 0 - 40 ppm dissolved O₂ (DO) |
| Relays | Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC). |
| Repeatability |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| ± 0.015 ppm or 2 % whichever is greater |
| Reproducibility | ± 0.02 ppm or 3 % whichever is greater |
|---|
| Response Time | (90%) <10 s (gas phase); <50 s (liquid phase) |
|---|
| Sample Flow Rate | 50 - 300 mL/min |
|---|
| Sample Pressure | 1 - 20 bar absolute (14.5 - 290 psi) |
|---|
| Sample Temperature | -5 - 50°C (23 - 122°F) |
|---|
| Sensors | K1100 LDO |
|---|
| Storage Conditions | -5 °C - 100 °C |
|---|
| Temperature Range | Accurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F) |
|---|
| Weight Sensor | 0.6 |
|---|
| What's included? | 410 panel mount controller, K1100 LDO sensor (high level), 3 m sensor cable, stainless steel flow-chamber with 6 mm fittings |
|---|