Hach, LPV3560DL.97.02, Sension+ EC5 DL Portable Conductivity/TDS Meter, Field Kit with 3 Poles Platinum Cell for General Purpose and Data Logger
Catalog Number: LPV3560DL.97.02
Send an RFQ.
Category
| Temperature correction | Linear |
|---|
| AC Power Adapter and USB/DC Adapter | No |
|---|---|
| Accuracy | Salinity: ≤ 0.5 % (± 1 digit) |
| Accuracy 2 | - |
| Accuracy 3 | - |
| Automatic Buffer Recognition | - |
| Backlight | Yes |
| Barometric Pressure Measurement | - |
| Calibration Curves Display | Slope and assymetry potential displayed |
| Compliance Certifications | CE.WEEE; RTTE directive see NB opinion statement; FCC approval |
| Conductivity Accuracy | ≤ 0.5 % (± 1 digit) of measurement range |
| Conductivity measurement | Yes |
| Conductivity Measurement Range | 0.01 µS/cm - 500 mS/cm 1 µS/cm - 200 mS/cm (probe range) |
| Conductivity resolution | Depending on the measurement range |
| Dimensions (H x W x D) | 38 mm x 73 mm x 186 mm |
| Display | Backlit LCD with pictograms |
| Display Type | 128 x 64 pixel, simultaneous readings |
| DO Measurement Range | - |
| DO Resolution | - |
| DO sensor calibration |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| - |
| Electrode stand | No |
|---|
| GLP Features | - |
|---|
| Height (Overall) | - |
|---|
| Inputs | MP-5 |
|---|
| Interface Languages | Icon based, no language needed |
|---|
| Internal Data Storage | 500 results |
|---|
| IP Rating | IP67 |
|---|
| Kit? | Yes |
|---|
| Languages | - |
|---|
| Manual Languages | Multi-lingual |
|---|
| Measurement Method | Interval, Auto stabilisation, continuous |
|---|
| Measuring Range ORP | - |
|---|
| Model | EC5 DL |
|---|
| mV Resolution | - |
|---|
| Operating Humidity | < 80 % relative humidity (non-condensing) |
|---|
| Operating Interface | Keypad |
|---|
| Operating Temperature | 0 - 50 °C (32 - 122 °F) |
|---|
| Outputs | Wireless to USB |
|---|
| Parameter | Conductivity, TDS, Salinity, Resistivity, Temperature |
|---|
| PC Data Transfer Software | Yes |
|---|
| pH Accuracy | - |
|---|
| pH Electrode calibration | - |
|---|
| pH Measurement Range | - |
|---|
| pH Resolution | - |
|---|
| Power Supply | Batteries (see Battery Requirements) |
|---|
| Pressure compensation | - |
|---|
| Probes included | 5060 Electrode |
|---|
| Resolution | EC: 0.01 µS/cm - 1 mS/cm|TDS: 1mg/L - 1g/L depending on range|Salinity: 0.1 mg/L - 0.1 g/L depending on range |
|---|
| Salinity Measurement Range | 0.0 - 1999 mg/L 2.0 - 50.0 g/L NaCl |
|---|
| Salinity Resolution | 0.1 - 1 mg/L or g/L NaCl |
|---|
| Simultaneous measurements | Conductivity (or TDS, or Salinity), Temperature |
|---|
| TDS Measurement Range | 0 mg/L - 500 g/L |
|---|
| TDS Resolution | 1 mg/L - 1 g/L |
|---|
| Temperature Accuracy | 0.2 °C (± 1 digit) |
|---|
| Temperature Compensation | Automatic or manual |
|---|
| Temperature Compensation | Automatic or manual |
|---|
| Temperature Measurement | -20.0 - 150.0 °C (-4.0 - 302.0 °F) |
|---|
| Temperature Resolution | 0.1 °C (0.1 °F) |
|---|
| Warranty | 36 months |
|---|
| Water Resistance | IP67 |
|---|
| Weight | 2.5 kg |
|---|
| What's included? | Includes: Sension+ EC5 Data Logger meter, Data Logger USB dongle, CD with PortCom software, Sension+ 5060 Platinum Conductivity Cell with temperature sensor, Sension+ portable field carrying case, 125mL of 147µS/cm, 1413µS/cm and 12.88mS/cm calibration standards, color coded screwable calibration tubes, sample and measurement containers, and user documentation. |
|---|