Hach, LPV4048.97.0002, Sension+ MM150 Portable Multi-Parameter meter, Field Kit with Multi Sensor for pH, ORP, Conductivity and TDS
Catalog Number: LPV4048.97.0002
Send an RFQ.
Category
| Temperature correction | Linear |
|---|
| AC Power Adapter and USB/DC Adapter | No |
|---|---|
| Accuracy | ORP: ±1 mV |
| Accuracy 2 | TDS: ≤ 0.5 % (± 1 digit) |
| Accuracy 3 | - |
| Automatic Buffer Recognition | pH 2.01, 4.01, 7.00, 9.21, 10.01 |
| Backlight | Yes |
| Barometric Pressure Measurement | - |
| Calibration Curves Display | Slope and assymetry potential displayed |
| Compliance Certifications | CE.WEEE |
| Conductivity Accuracy | ≤ 0.5 % (± 1 digit) of measurement range |
| Conductivity measurement | Yes |
| Conductivity Measurement Range | 0.01 µS/cm - 500 mS/cm 1 µS/cm - 30 mS/cm (probe range) |
| Conductivity resolution | Depending on the measurement range |
| Dimensions (H x W x D) | 38 mm x 73 mm x 186 mm |
| Display | Backlit LCD with pictograms |
| Display Type | 128 x 64 pixel, simultaneous readings |
| DO Measurement Range | - |
| DO Resolution | - |
| DO sensor calibration | - |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Electrode stand | No |
|---|
| GLP Features | - |
|---|
| Height (Overall) | - |
|---|
| Inputs | MP-8 |
|---|
| Interface Languages | Icon based, no language needed |
|---|
| Internal Data Storage | - |
|---|
| IP Rating | IP67 |
|---|
| Kit? | Yes |
|---|
| Languages | - |
|---|
| Manual Languages | Multi-lingual |
|---|
| Measurement Method | Auto stabilisation, continuous |
|---|
| Measuring Range ORP | ± 1999 mV |
|---|
| Model | MM150 |
|---|
| mV Resolution | 0.1 mV (0 - 200 mV) 1 mV (for rest of range) |
|---|
| Operating Humidity | < 80 % relative humidity (non-condensing) |
|---|
| Operating Interface | Keypad |
|---|
| Operating Temperature | 0 - 50 °C (32 - 122 °F) |
|---|
| Outputs | - |
|---|
| Parameter | pH, mV, ORP/Redox, Conductivity, TDS, Salinity, Resistivity, Temperature |
|---|
| PC Data Transfer Software | - |
|---|
| pH Accuracy | ≤ 0.02 pH (± 1 digit) |
|---|
| pH Electrode calibration | 1 to 3 points calibration |
|---|
| pH Measurement Range | -2.00 - 19.99 pH |
|---|
| pH Resolution | 0.01 pH |
|---|
| Power Supply | Batteries (see Battery Requirements) |
|---|
| Pressure compensation | - |
|---|
| Probes included | 5048 Electrode |
|---|
| Resolution | pH: 0.01|ORP: 1 mV|EC: 0.01 µS/cm - 1 mS/cm depending on range|TDS: 1 mg/L - 1 g/L depending on range |
|---|
| Salinity Measurement Range | - |
|---|
| Salinity Resolution | - |
|---|
| Simultaneous measurements | pH, ORP, Conductivity (or TDS), Temperature |
|---|
| TDS Measurement Range | 0 mg/L - 500 g/L |
|---|
| TDS Resolution | 1 mg/L - 1 g/L |
|---|
| Temperature Accuracy | 0.2 °C (± 1 digit) |
|---|
| Temperature Compensation | Automatic or manual |
|---|
| Temperature Compensation | Automatic or manual |
|---|
| Temperature Measurement | -20.0 - 150.0 °C (-4.0 - 302.0 °F) |
|---|
| Temperature Resolution | 0.1 °C (0.1 °F) |
|---|
| Warranty | 36 months |
|---|
| Water Resistance | IP67 |
|---|
| Weight | 0.3 kg |
|---|
| What's included? | Includes: Sension+ MM150 meter, Sension+ 5048 multi sensor for pH, ORP and Conductivity with temperature sensor, Sension+ portable field carrying case, 125mL of pH4, pH7 and pH10 calibration standards, 147µS/cm, 1413µS/cm and 12.88mS/cm calibration standards, 220mV ORP calibration standard, color coded screwable calibration tubes, sample and measurement containers, electrode storage solution and user documentation. |
|---|