Hach, LPV448.99.00501, QP1680 High-Temperature TOC Laboratory Analyzer, with auto sampler, 96 positions
Catalog Number: LPV448.99.00501
Send an RFQ.
Category
Pack Size100 pcs / pack
| Ambient Temperature | -20 - 60 °C (-4 - 140 °F) |
|---|---|
| Analysis time | Approx. 3 minutes |
| Dimensions | 440 x 380 x 700 mm / 17.3 x 15 x 27.6 in. (H x W x D) |
| Gas consumption | 150 mL/min* *Sample preparation for NPOC determination requires additional 300-350 mL/min. |
| Gas specifications | Oxygen or synthetic air: minimum 99.998% (4.8) at 3 - 10 bar |
| Lower Limit of Detection (LOD) | TC, TOC, NPOC: 50 µg/L |
| Measurement Method | NDIR (non-dispersive Infrared Detection) |
| Model | QP1680-TOC |
| Norms and Standards | TOC / NPOC: ASTM D7573, EN 1484, EPA 415.1, EPA 9060A, ISO 8245, SM 5310B, NEN-ISO 20236 |
| Number of sample positions | 96 |
| Operating Conditions | 20 - 30 °C (68 - 86 °F); 20 - 80% relative humidity (non-condensing) |
| Oxidation Method | Catalytic combustion at 680 °C |
| Parameter | TOC |
| Pollution Degree | 2 |
| Power | Analyzer: 750 W max. PC: 90 W max. Monitor: 100 W max. |
| Power Supply | Analyzer: 100 - 240 VAC, 50/60 Hz, 16 A, with protective grounding PC: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding Monitor: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Range | TC, TIC, NPOC: 0 - 30000 mg/L |
|---|
| Repeatability | Up to 10 mg/L TC, TIC, NPOC, TN: < 5% > 10 mg/L TC, TIC, NPOC, TN: < 2% |
|---|
| Sample Volume | 10 - 1000 µL |
|---|
| Temperature | Furnace temperature max. 1050 °C (1922 °F) (depending on configuration) |
|---|
| Warranty | 12 months |
|---|
| Weight | Approx. 31 kg (68.3 lbs) |
|---|
| What's included? | TOC Instrument Sample tray with 96 positions for 24 mL vials Glass sample vials 24 mL (100 pcs) USB 2.0 cable A-B Set of tubing PTFE blue-stripe 1/8" OD length 2 m including nut & ferrule Reagent container with screwcap for UPW, Acid and Waste Power cord USB storage device with software, test results and Full User Manual Printed User Manual |
|---|