Hach, LYP106.99.01004, Standard Analyzer SCP Panel, Medium Pressure, ˂600 psig (41.4 bar), ˂600 °F (315 °C)
Catalog Number: LYP106.99.01004
Send an RFQ.
Category
| Application | Make up water, feed water, boiler water, condensate and steam in medium pressure boilers for Power & Industry |
|---|---|
| Cooling Water | Filtered, softened/decarbonized water quality required |
| Permissible Chloride Range | < 250 mg/L for sample temperature 77 - 356 °F (25 - 180 °C) <100 mg/L for sample temperature 356 - 554 °F (180 - 290 °C) <25 mg/L for sample temperature 554 - 1022 °F (290 - 550 °C) |
| pH Range | 7 - 12 pH |
| Pressure Range | Cooling water: <150 psig (10.3 bar) |
| Sample Flow Rate | 200 mL/min for conductivity 150 mL/min for SiO₂ and PO₄ 100 mL/min for pH, O₂, Na Plus 350 mL/min for grab sample Maximum total sample flow for the panel is 1600 mL/min for hot water or 1000 mL/min for steam. Up to 3 analyzers can be connected to one sampling panel. |
| Sample Pressure | Liquid: 50 - 500 psig (3.4 - 34.4 bar) Steam: 300 - 500 psig (20.7 - 34.4 bar) |
| Sample Temperature | < 600 °F (315 °C) |
| Temperature | Cooling water: <110 °F (43 °C) |
| Turbidity | < 50 NTU |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| What's included? |
|---|
| Sample Conditioning Panel for online analysis, consisting of the following components: Sentry Back Pressure Relief Valve with a Set-point of 20 psig (1.4 bar), Grab Sample, 304 SS Sample Sink; all components are factory mounted on a 12 in. (W) x 36 in. (H), T304SS backplate. All sample tubing throughout panel is SA249, T316 SS. Cooling Water Valve Materials are Stainless Steel. Sentry Thermal Shut off Valve with a Set-point of 120 °F (49 °C). Low Pressure (Cooled Sample) Blow-down Valve, Total Flow Indicator; 0-1600 cc/min, Temperature Gauge; 0-250 °F (-20-120 °C) Pressure Gauge; 0-60 psig (0-4 bar). Globe Valve on the Cooling Water Outlet. 3-Way Cooling Water Inlet Valve with drain. 1/4 in. Sample Inlet Isolation Valve. Primary Sample Cooler, Sentry Model TLR4225. Sample Flow Control Valve. |