Send an RFQ for Mettler-Toledo 52206318, DO Sensor InPro6900i/12/220. Iright supports global sourcing and international shipment for life science and laboratory products.
| Measurement Parameter | Oxygen |
|---|---|
| Measurement Technology | Amperometric/Polarographic |
| Accuracy | ≤ ± [1 % +0.1 ppb] |
| Response Time | T98 = < 90 s @ 25°C (77°F)(air to N2) |
| Primary Media/Application | Food and Beverage |
| IP Rating | IP68 |
| ISM (Digital) or Analog | ISM (Digital) |
| Wetted Metallic Material | 316L stainless steel |
| Surface Roughnes of Wetted Material | N5/Ra16 (Ra=0.4μm/16μin) |
| Sensor Diameter | 12mm |
| O-Ring Material | Silicone |
| Process Connection | Pg 13.5 |
| Sensor Length | 220 mm |
| Wetted membrane material | PTFE |
| Connector Design | Straight |
| Model Family | InPro 6900/6900i/6950i |
| Autoclavable/Sterilizable | Yes |
| CIP resistant | Yes |
| Mechanical Temp. Range | 23 °F – 249.8 °F (-5 °C – 121 °C) |
| Operating Pressure (Bar) | 0.2–6 Bar |
| Operating Pressure (PSI) | 0–87 PSI |
| Design Pressure | 174 psi (12 bar) |
| Cable Connector | K8S (IP68) |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Hygienic/Biocompatibility Approvals |
|---|
| FDA/USP Class 7 |
| Hazardous Area Approvals | ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb Ex ia IIIC T69°C/T81°C/T109°C/T161°C Da/Db FM: IS / I, II, III / 1 / ABCDEFG/ T6 Ta=60 °C - 53 800 002 Entity |
|---|
| Certificates & Approvals | Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV, EHEDG |
|---|
| Sensor signal in air at 25 °C (77 °F) | 250 to 500 nA |
|---|
| Measurement Range | 0-100% O2 saturation |
|---|
| Operating Range | 1 ppb - O2 sat. |
|---|
| Sterilizable/Autoclavable | Yes |
|---|
| Residual signal in oxygen free media | <0.03% of signal in ambient air |
|---|
| Measured Pressure Resistance | 0.2 bar – 9 bar |
|---|
| Measuring Temp. Range | 32 °F – 176 °F (0 °C – 80 °C) |
|---|
| Detection limit | 1 ppb |
|---|