Send an RFQ for Mettler-Toledo 58045001, Bioburden Analyzer 7000RMS Online. Iright supports global sourcing and international shipment for life science and laboratory products.
| Operating Range (Temp.) | 0 °C – 37 °C |
|---|---|
| Operating Range (Humidity) | 10 % – 90 % |
| Flow Rate | 30 mL/min – 100 mL/min |
| Dimensions (HxWxD) | 616 mm x 564 mm x 305 mm |
| Analysis Time | Continuous |
| Wall Mount | Anti-vibration shelf required (P/N 58 079 700) |
| Minimum detection size | ≥ 0.3 μm |
| Inlet pressure | 21 - 80 psig (2 - 5.5 bar(g)) Calibration, cleaning and grab sample requires sample pressure of 0 psig (0 bar(g) Process pressure above 80 psig (5.5 bar(g)) requires optional High Pressure Regulator (P/N 58 091 552) |
| Humidity (non-condensing) | 80% maximum relative humidity up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F) |
| Ambient temperature (non-condensing) | 1 - 37 °C (32 - 98.6 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included) |
| Voltage | MAINS supply voltage fluctuations up to ±10% of the nominal voltage of 100 - 240 VAC 50 - 60 Hz TEMPORARY OVERVOLTAGES occurring on the MAINS SUPPLY TRANSIENT OVERVOLTAGES: up to levels of OVERVOLTAGE CATEGORY II |
| Data communication |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| 5 - 20 mA standard, with configurable output ranges Analog output channels Ethernet - standard RJ 45 / Wi-Fi capable SCADA connectivity via Modbus TCP USB |
| Enclosure Material | Stainless Steel |
|---|
| Measurement Range | 1 -10,000 AFU / mL |
|---|
| Response Time | 3 seconds (1 mL) |
|---|
| Physical dimensions | (WxHxD) 22.2"(56.4 cm) W x 24.25"(61.6 cm) H x 12"(30.5 cm) D |
|---|
| Monitoring location | At-line to drain |
|---|
| Flow rate | 31 mL/min |
|---|
| Use | Indoor use |
|---|
| Environmental Temperature | 6 - 35 °C (41- 95 °F) |
|---|
| Weight | 73.4 lbs (33.3 kg) |
|---|
| Outlet connection | 0.125" (3 mm) O.D. |
|---|
| Inlet connection | 0.125" (3 mm) O.D. |
|---|
| Power Requirements | 100 - 240 VAC 50 - 60 Hz 5A Use the power cord included with the instrument 8.2' (2.5 m) cord length provided standard |
|---|
| Temperature (non-condensing) | 6 - 90 °C (41-194 °F) Temperature below 15 °C or above 45 °C requires Sample Conditioning Coil (included) |
|---|
| Environment | Pollution degree 3 |
|---|
| Detection limit | 2 AFU (Auto Fluorescent Units) |
|---|
| Type / Quality | Purified Water (PW), Ultrapure Water (UPW), Water for Injection (WFI) |
|---|
| Altitude | Up to 6562' (2000 m) |
|---|