Description
Overview
Cyclin E1 (CCNE1) is a member of the highly conserved cyclin family, whose members have various roles in the cell cycle. CCNE1 forms a complex with cyclin-dependent kinase 2 (CDK2) and acts as a regulatory subunit. CDK2 is required for cell cycle G1/S transition. Overexpression of CCNE1 has been observed in many tumors, such as breast, ovarian, endometrial, and bladder cancer.
The AlphaLISA
SureFire
Human Total Cyclin E1 Detection Kit is a sandwich immunoassay for the quantitative detection of total Cyclin E1 in cellular lysates, using Alpha Technology.
Formats
The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.
AlphaLISA SureFire Ultra kits are compatible with
Cell and tissue lysates
Antibody modulators
Biotherapeutic antibodies
Alpha SureFire kits can be used for
Cellular kinase assays
Receptor activation studies
Screening
How it works
Total-AlphaLISA
SureFire Ultra
assay principle
The Total-AlphaLISA
SureFire Ultra
assay measures the expression level of a protein target in a cell lysate.
The Total-AlphaLISA
SureFire Ultra
assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.
Total-AlphaLISA
SureFire Ultra
two-plate assay protocol
The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA
SureFire Ultra
detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.
Total-AlphaLISA
SureFire Ultra
one-plate assay protocol
Detection of Total target protein with AlphaLISA
SureFire Ultra
reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA
SureFire Ultra
quality.
Assay versatility
Versatility of Total Cyclin E1 assay in various cell lines
Adherent cells were seeded at 20,000 cells/well in a 96-well culture plate in complete medium and incubated overnight at 37°C, 5% CO2. Cells were lysed with 100 µL of Lysis Buffer.
Cyclin E1 levels were evaluated by AlphaLISA
SureFire Ultra.
For the detection step, 10 µL of cell lysate (approximately 2,000 cells) was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor Mix and incubated for 1 hour at RT. Finally, 5 µL of Donor Mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.
As expected, Cyclin E1 is expressed at high levels in BeWo cells.