Description
Overview
Protein Kinase C theta (PKCθ) is a calcium-independent, diacylglycerol-activated serine/threonine kinase that plays a central role in T cell activation and immune responses. PKCθ is recruited to the immunological synapse upon T cell receptor (TCR) engagement, where it phosphorylates key substrates including CARMA1, leading to NF-κB activation and IL-2 production. It is essential for T cell proliferation, differentiation, and effector function, particularly in CD4+ T helper cells and CD8+ T cells. PKCθ also regulates T cell survival and memory formation. Dysregulation of PKCθ contributes to autoimmune diseases, transplant rejection, and T cell malignancies. Selective PKCθ inhibitors are being developed as immunosuppressive agents for autoimmune disorders and as potential cancer therapeutics to modulate T cell-mediated immunity and overcome immune evasion mechanisms.
The AlphaLISA
SureFire Ultra
Human and Mouse Total PKCθ is a sandwich immunoassay for the quantitative detection of total PKCθ in cellular lysates, using Alpha Technology.
Formats:
The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.
AlphaLISA
SureFire Ultra
kits are compatible with:
Cell and tissue lysates
Antibody modulators
Biotherapeutic antibodies
AlphaLISA
SureFire Ultra
kits can be used for:
Cellular kinase assays
Receptor activation studies
High-throughput screening for preclinical studies
How it works
Total-AlphaLISA
SureFire Ultra
assay principle
The Total-AlphaLISA
SureFire Ultra
assay measures the expression level of a protein target in a cell lysate.
The Total-AlphaLISA
SureFire Ultra
assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with streptavidin to capture one of the detection antibodies, which is biotinylated. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.
Total-AlphaLISA
SureFire Ultra
two-plate assay protocol
The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well OptiPlate™ plate before the addition of Total-AlphaLISA
SureFire Ultra
detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.
Total-AlphaLISA
SureFire Ultra
one-plate assay protocol
Detection of Total target protein with AlphaLISA
SureFire Ultra
reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining AlphaLISA
SureFire Ultra
quality.
Assay versatility
Selectivity of PKCθ Total assay
Selectivity of the Total PKCθ assay was assessed by assaying recombinant PKCθ protein.
Dilutions of recombinant PKCθ protein (Abcam ab56641) were prepared in Lysis Buffer and evaluated using the AlphaLISA
SureFire Ultra
assay. For the detection step, 10 µL of protein was transferred into a 384-well white OptiPlate, followed by 5 µL of Acceptor mix and incubated for 1 hour at room temperature. Finally, 5 µL of Donor mix was then added to each well and incubated for 1 hour at RT in the dark. The plate was read on an Envision using standard AlphaLISA settings.