Description
Overview
Extracellular signal-regulated kinases 1/2 (ERK1/2) are central components of the MAPK signaling cascade, regulating cell growth, survival, and differentiation. Activated by MEK1/2 through phosphorylation, ERK1/2 phosphorylate diverse cytoplasmic and nuclear targets. ERK1/2 dysregulation is associated with cancer, driving tumor proliferation and resistance to therapy, and with neurodegenerative diseases like Alzheimer's, where it influences amyloid plaque formation.
The AlphaLISA
SureFire
Biotin-Free Human and Mouse Total ERK1/2 Detection Kit is a sandwich immunoassay for the quantitative detection of total ERK1/2 in cellular lysates, using Alpha Technology.
Formats:
The HV (high volume) kit contains reagents to run 100 wells in 96-well format, using a 60 μL reaction volume.
The 500-point kit contains enough reagents to run 500 wells in 384-well format, using a 20 μL reaction volume.
The 10,000-point kit contains enough reagents to run 10,000 wells in 384-well format, using a 20 μL reaction volume.
The 50,000-point kit contains enough reagents to run 50,000 wells in 384-well format, using a 20 μL reaction volume.
AlphaLISA
SureFire
Biotin Free kits are compatible with:
Cell and tissue lysates
Antibody modulators
Biotherapeutic antibodies
Biotin rich samples
AlphaLISA
SureFire
Biotin Free kits can be used for:
Cellular kinase assays
Receptor activation studies
High-throughput screening for preclinical studies
How it works
Total-AlphaLISA
SureFire
Biotin Free assay principle
The Total-AlphaLISA
Surefire
Biotin Free assay measures the expression level of a protein target in a cell lysate.
The Total-AlphaLISA
Surefire
assay uses two antibodies which recognize two different distal epitopes on the targeted protein. AlphaLISA assays require two bead types: Acceptor and Donor beads. Acceptor beads are coated with a proprietary CaptSure™ agent to specifically immobilize the assay specific antibody, labeled with a CaptSure tag. Donor beads are coated with a proprietary CaptSure 3 agent to capture one of the detection antibodies, which is labeled with CaptSure 3 tag. In the presence of targeted protein, the two antibodies bring the Donor and Acceptor beads in close proximity whereby the singlet oxygen transfers energy to excite the Acceptor bead, allowing the generation of a luminescent Alpha signal. The amount of light emission is directly proportional to the quantity of protein present in the sample.
Total-AlphaLISA
SureFire
Biotin Free two-plate assay protocol
The two-plate protocol involves culturing and treating the cells in a 96-well plate before lysis, then transferring lysates into a 384-well Optiplate™ plate before the addition of Total-AlphaLISA
SureFire
Biotin Free detection reagents. This protocol permits the cells viability and confluence to be monitored. In addition, lysates from a single well can be used to measure multiple targets.
Total-AlphaLISA
SureFire
one-plate assay protocol
Detection of Total target protein with AlphaLISA
SureFire
Biotin Free reagents can be performed in a single plate used for culturing, treatment, and lysis. No washing steps are required. This HTS designed protocol allows for miniaturization while maintaining robust AlphaLISA
SureFire
quality.