| Application | Mammalian cell culture; Insect cell culture; Microbial Fermentation; Low molecular weight binding; Shear-stress-sensitive cells such as stem cells |
|---|---|
| Application Area | Preclinical and clinical studies |
| Biocompatibility (USP Class VI) | USP Class VI and | or ISO 10993 conformity; USP <85>; USP <87> | ISO 10993-5; USP <88>; USP <788> |
|---|
| Gas Filters | HEPA rated hydrophobic filter |
|---|
| Connector Gender | Female; Male |
|---|---|
| Connector(s) | Luer lock; MPC; Clave needleless sampling port |
| Device/Instrument Compatibility | Biostat® RM 20 | 50 L |
|---|---|
| Screw Cap | No |
| Sensors | Optical DO; Optical pH |
| pH Range | pH 6.0 – 8.0 |
|---|
Answer:Nominal capacity is 20 L, with a specified working range of 2–10 L.
Answer:It contains optical pH and optical dissolved-oxygen sensors.
Answer:The product is supplied as five sterile Flexsafe RM bags.
Flexsafe® RM Optical is a sterile single-use rocking-motion bioreactor bag designed for cultivation on compatible Biostat® RM 20/50 L equipment. This 20 L configuration incorporates pre-calibrated optical pH and dissolved oxygen sensors, supporting continuous monitoring without a reusable probe contacting the culture. The stated working-volume range is 2–10 L. The polyethylene-film bag supports low-shear wave mixing for mammalian cells and selected other culture processes and can be integrated into qualified instrument-control workflows. This version does not include a screw cap and is supplied as five sterile bags. The assembly provides a disposable cultivation chamber with appropriate ports and gas filters; its nominal bag capacity should not be confused with the smaller recommended working volume.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Film Material | Film S80: Polyethylene (PE) |
|---|
| Operating Conditions - Temperature | 16 – 40°C (specified by the hardware) |
|---|
| Pressure Range | Operation pressure: 6 mbar [g] - 30 mbar [g] |
|---|
| Bag Type | Rocking Motion Bag - Optical |
|---|---|
| Brand | Flexsafe® RM |
| Pack Size | 5 |
| Type of Sensor | Optical pH & Optical DO |
| Delivery Condition | Sterile |
|---|
| Volume | 20 L |
|---|---|
| Working Volume | 2 – 10 L |