| Application | Mammalian cell culture; Insect cell culture; Microbial Fermentation; Low molecular weight binding; Shear-stress-sensitive cells such as stem cells |
|---|---|
| Application Area | Preclinical and clinical studies |
| Biocompatibility (USP Class VI) | USP Class VI and | or ISO 10993 conformity; USP <85>; USP <87> | ISO 10993-5; USP <88>; USP <788> |
|---|
| Gas Filters | HEPA rated hydrophobic filter |
|---|
| Connector Gender | Female; Male |
|---|---|
| Connector(s) | Luer lock; MPC; Clave needleless sampling port; Opta® SFT Connector |
| Device/Instrument Compatibility | Biostat® RM 200 L |
|---|---|
| Screw Cap | No |
| Sensors | Optical DO; Optical pH |
| pH Range | pH 6.0 – 8.0 |
|---|
Answer:It is a 100 L Flexsafe RM rocking-motion bag configured for external ATF perfusion.
Answer:No. The ATF variant is designed to connect to an external ATF module.
Answer:The published working-volume range is 10–50 L, with two bags supplied.
Flexsafe® RM 100 L Perfusion ATF is a single-use rocking-motion bioreactor bag configured for connection to an external alternating tangential flow (ATF) perfusion system. The assembly is used with compatible Biostat® RM hardware for low-shear mammalian-cell cultivation and process development. This 100 L nominal bag has a specified 10–50 L working-volume range and incorporates optical pH and dissolved oxygen sensors for process monitoring. The ATF connection enables cell-retention perfusion through an external module; it is distinct from RM bags with an integrated 1.2 µm perfusion membrane. The assembly uses polyethylene film and is delivered sterile. The product is supplied as two bags and supports repeated media exchange during controlled bioreactor cultivation.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Film Material | Film S80: Polyethylene (PE) |
|---|
| Operating Conditions - Temperature | 16 – 40°C (specified by the hardware) |
|---|
| Pressure Range | Operation pressure: 6 mbar [g] - 30 mbar [g] |
|---|
| Bag Type | Rocking Motion Bag - Perfusion with Connection to ATF Module |
|---|---|
| Brand | Flexsafe® RM |
| Pack Size | 2 |
| Type of Sensor | Optical pH & Optical DO |
| Delivery Condition | Sterile |
|---|
| Volume | 100 L |
|---|---|
| Working Volume | 10 – 50 L |