| Chemistry | C18 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Hybrid |
| pH Range Min | 2 pH |
| pH Range Max | 11 pH |
| Maximum Pressure | 18000 psi (1240 Bar) |
| Endcapped | Yes |
| Bonding Technology | Shield RP18 |
| Silanol Activity | Low |
| Particle Shape | Spherical |
| Particle Size | 1.7 µm |
| Endfitting Type | Parker-style |
| Pore Size | 130 Å |
| Format | Column |
| Surface Area | 185 |
| System | UPLC, UHPLC |
| Particle Technology | BEH |
| USP Classification | L1 |
| Inner Diameter | 2.1 mm |
| Length | 50 mm |
| Carbon Load | 17 % |
| eCord | Yes |
| UNSPSC | 41115709 |
| Brand | ACQUITY UPLC |
| Product Type | Columns |
| Units per Package | 1 pk |
Answer:It contains an embedded carbamate group that provides alternate selectivity, especially for phenolic compounds.
Answer:The column supports up to 18,000 psi (1240 bar) and a pH range of 2–11.
Answer:It uses 1.7 µm BEH hybrid particles with a 130 Å pore size in a 2.1 mm ID × 50 mm format.
ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk is used for high-efficiency reversed-phase UPLC and UHPLC method development when an embedded-polar-group phase can provide useful alternate selectivity. The column uses BEH hybrid particles with Shield RP18 bonding that incorporates an embedded carbamate group. This chemistry changes selectivity relative to straight-chain alkyl phases and is particularly useful for phenolic compounds. The spherical particles are 1.7 µm with a 130 Å pore size; the phase is endcapped, has low silanol activity, and carries a 17% carbon load. The 2.1 mm inner diameter × 50 mm format is designed for fast UPLC/UHPLC separations and supports pressures up to 18,000 psi (1240 bar). The pH range is 2–11, giving the phase broad method-development flexibility. This combination of sub-2 µm particles, hybrid substrate, embedded-polar-group selectivity, and high pressure tolerance makes the column suitable for rapid analytical methods that need both high efficiency and a selectivity profile different from standard C18 or C8 phases. The column also includes eCord functionality.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.