| Chemistry | C8 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Hybrid |
| pH Range Min | 1 pH |
| pH Range Max | 12 pH |
| Maximum Pressure | 6000 psi (415 Bar) |
| Endcapped | Yes |
| Silanol Activity | Low |
| Particle Shape | Spherical |
| Particle Size | 5 µm |
| Endfitting Type | Waters |
| Pore Size | 130 Å |
| Format | Column |
| Surface Area | 185 |
| System | HPLC |
| Particle Technology | BEH |
| USP Classification | L7 |
| Inner Diameter | 2.1 mm |
| Length | 150 mm |
| Carbon Load | 13 % |
| UNSPSC | 41115709 |
| Brand | XBridge |
| Product Type | Columns |
| Units per Package | 1 pk |
Answer:The column is 2.1 × 150 mm, containing 5 µm BEH particles with 130 Å pores.
Answer:C8 generally offers lower hydrophobic retention than a comparable C18 phase, which can shorten elution of strongly retained compounds.
Answer:The specified pH range is 1–12 and maximum pressure is 6000 psi (about 415 bar).
Waters XBridge BEH C8 columns use an endcapped, trifunctionally bonded C8 phase on ethylene-bridged hybrid particles for robust reversed-phase HPLC separations. The analytical column measures 2.1 mm internal diameter by 150 mm length, with 5 µm particles and 130 Å pores. Its specified mobile-phase pH range is 1–12 and maximum operating pressure is 6000 psi, approximately 415 bar. Compared with the C18 version of the same family, the C8 phase generally provides lower hydrophobic retention, which can shorten analysis times for compounds that retain excessively on C18. The 2.1 mm bore supports reduced mobile-phase consumption when flow rates and system dispersion are appropriately scaled. Use well-prepared samples and compatible aqueous–organic solvents, then equilibrate the stationary phase before sample analysis. Check column pressure, retention and peak shape routinely, and select a method within the specified temperature, pH and pressure conditions. One analytical column is supplied.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.