Bio-Rad, LNK203CY3, Cy3 Conjugation Kit
Size: 3 Conjugations For 20µg Antibody, LYNX Rapid Plus Cy3 Antibody Conjugation Kit
Catalog Number: LNK203CY3
Send an RFQ.
Category
Pack Size3 vials
| Regulatory | For research purposes only. |
|---|---|
| Guarantee | 12 months from date of despatch. |
| Product Type | Conjugation Kit |
| Specificity | Cy3 Conjugation Kit |
| Reagents In The Kit | 3 Vials LYNX Rapid Plus lyophilized Cy3 mix 1 Vial LYNX Rapid Plus Modifier reagent 1 Vial LYNX Rapid Plus Quencher reagent. |
| Preparing The Antibody | LNK203CY3 The following buffer solutions are recommended for preparing the antibody: 10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5. Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNX chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency. It is recommended that 10-20μg antibody be used in each labeling reaction. For optimal results the antibody should be at a concentration of 1mg/ml, with a maximum volume of 10μl and a recommended antibody amount of 10μg. A maximum of 20μg of antibody can be used to obtain good quality conjugates as long as the maximum conjugation volume of 10μl is not exceeded. Antibody below 1mg/ml can still be used as long as the maximum volume is not exceeded. Using less than the recommended amount of antibody may result in unbound label, but this will be removed during subsequent application wash steps. Antibody below 0.5mg/ml should be concentrated before use with the kit. |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Acknowledgements | This product or portions thereof is manufactured under license from Carnegie Mellon University under U.S. Patent Number 5,268,486 and related patents. Cy and CyDye are trademarks of GE Healthcare Limited. |
|---|
| Licensed Use | Bio-Rad LYNX conjugation kits are offered for research purposes alone, and are not intended for human, therapeutic or diagnostic use. The purchase of this conjugation kit conveys to the buyer (whether the buyer is a not-for-profit, academic or for-profit entity) the non-transferable right to use the amount of product purchased and the components of the product for in-house research. The buyer shall not sell or otherwise transfer this product, its components, or materials prepared therefrom to any third party. The buyer shall not use this product or its components for commercial purposes. For the avoidance of doubt, ‘commercial purposes’ means any activity by a party for consideration and includes, without limitation, use of the product or its components (I) in the manufacturing of conjugated materials (e.g. labeled antibodies), (ii) to provide a service, information or data, (iii) for therapeutic, diagnostic or prophylactic purposes, or (iv) for repackaging/resale, whether or not such product or its components are resold for use in research. The use of this product by the buyer constitutes agreement with the terms of this limited use label license for LYNX products. |
|---|