| Volume | 250 mL |
|---|---|
| Bottle Material | PETG |
| Feed Line | 1/4" ID Lifemeta™ STF TPE with Tubing Plug |
| Product Name | Lifecube™ SSB Bottle Assemblies |
|---|---|
| Bottle Volume | 125 mL, 250 mL, 500 mL, 1 L |
| Number of Port | 2 (1 feed line, 1 vent line) |
| Operating Temperature | PETG Bottle: -40 to 60°C PC Bottle: -80 to 121°C |
| Bottle Material | PETG or PC |
|---|---|
| Cap Material | Polypropylene (PP) |
| Type 1 | Feed line: 1/4" ID Lifemeta™ STT Silicone (20 cm) + Metallic Sleeve + ECS Female Connector Vent line: 1/8" ID Lifemeta™ STT Silicone (10 cm)+ Vent Filter Dip tube: 1/8" Lifemeta™ STT Silicone |
|---|---|
| Type 2 | Feed line: 1/4" ID Lifemeta™ STF TPE (40 cm) + Plug Vent line: 1/8" ID Lifemeta™ STT Silicone (10 cm) + Vent Filter Dip tube: 1/8" Lifemeta™ STT Silicone |
Answer:The sterile vessel holds 250 mL, with a PETG bottle body and polypropylene two-port screw cap.
Answer:The feed port uses 40 cm Lifemeta STF TPE tubing with a tubing plug; a second port supports filtered venting.
Answer:No. The PETG bottle assembly is supplied gamma sterilized and is not intended for autoclaving.
Lifecube SSB 250 mL single-use media bottle assemblies provide a sterile vessel and preassembled fluid connections for preparing, holding, and transferring culture media, buffers, sera, and other bioprocess liquids. The transparent PETG bottle is fitted with a polypropylene two-port screw cap. One port is connected to a 40 cm thermoplastic elastomer feed line terminated with a tubing plug; the second incorporates a short silicone vent line with a vent filter. An internal silicone dip tube supports liquid withdrawal from the bottle. The PETG bottle is specified for operation from −40 to 60 °C and is gamma sterilized before delivery. PETG assemblies should not be autoclaved. The Lifemeta STF TPE feed tubing has a nominal 1/4-inch internal diameter, while the vent line uses nominal 1/8-inch ID silicone tubing. The bottle configuration is suited to small-volume sterile solution preparation and transfer, where a sealed fluid path reduces repeated manual opening. Check connector compatibility, extractables requirements, and validated operating limits before incorporating the assembly into a process.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Compliance |
|---|
| USP <788> Particulate Matter USP <87> Cytotoxicity USP <88> Biological Reactivity FDA Indirect Food Additives, 21 CFR 177-182 ADCF Materials |
| Bacterial Endotoxin | Endotoxin Limit of WFI System<0.25 EU/mL with the Limulus Amebocyte Lysate (LAL), USP <85> |
|---|
| Delivery Condition | Sterile |
|---|---|
| Sterilization Method | Gamma irradiation at 25–45 kGy |
| Pack Size | Pack of 10 |
|---|---|
| Packaging | Individually packed in double PE bag |