Send an RFQ for Hamilton 243110, OxyGold G Arc 120. Iright supports global sourcing and international shipment for life science and laboratory products.
| Process Connection | PG13,5 |
|---|---|
| Sensor Family | OxyGold G |
| Wetted Parts | Stainless Steel 1.4435; EPDM (Ethylene propylene elastomer); FKM (Fluorocarbon Elastomer); VMQ (Silicone elastomer); See compliance details in Material Specification document |
| Electrical Connector | VP8 |
| Measuring Range | 1 ppb to 40 ppm (DO) or 0.02 to 1000 mbar (pO₂) |
| Electrolyte | Oxylyte G |
| Accuracy at 25 °C | ± 2% |
| Drift at Room Temperature | < 1% per week |
| Membrane Cap | Standard |
| Oxygen Consumption | Ca. 100 ng/h in air at 25 °C |
| Temperature Sensor | NTC 22 kOhm |
| Configurable Values | Dissolved oxygen (DO): mbar,%-sat,%-vol, μg/l ppb, mg/l ppm, ppm gas; Temperature: °C, °F, K |
| Surface Quality of Steel | Ra < 0.4 µm (N5) |
| Electrode system | Silver platinum combination |
| Analog Interface 1 | 4 to 20 mA for DO, programmable |
| Analog Interface 2 | 4 to 20 mA for Temp., programmable |
| Analog Interface 1 and 2 | Galvanically not isolated; pulse width modulation 3.5 kHz |
| Baud Rate | 4800, 9600, 19200, 38400, 57600, 115200 Bd |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Polarization Voltage and Time | -670 ± 50 mV, ≥ 2 hours |
|---|
| Operating Voltage | 7 to 30 VDC max. 150 mW |
|---|
| Serial Number | Yes |
|---|
| Response Time | t98% 30 to 60 s at 25 °C, from air to nitrogen |
|---|
| Certificate | Yes, with parameter settings and materials used |
|---|
| ATEX Approval | No |
|---|
| Diameter | 12 mm |
|---|
| Autoclavable | Yes |
|---|
| Steam Sterilizable | Yes |
|---|
| CIP | Yes |
|---|
| Operating Temperature Range | Analog interface: 0 to 110 °C; Digital interface: 0 to 130 °C |
|---|
| Pressure Range bar g | 0 to 12 bar |
|---|
| Max. CO₂ Partial Pressure | 0.01 bar |
|---|
| Required Flow | ≥ 0.1 m/s |
|---|
| Automatic Polarization | Yes, max. 2 hours stabilisation time |
|---|