Send an RFQ for Mettler-Toledo 30571932, Analyzer 2850Si Silica 2/Enc. Iright supports global sourcing and international shipment for life science and laboratory products.
| Silica measurement range | 0-5000 ppb, limit of detection per ASTM Method D7126 |
|---|---|
| Operating Range (Temp.) | 5 °C – 60 °C 41 °F – 140 °F |
| Sample Flow rate | 50 – 250 mL / min |
| Process Connection | Sample inlet: 6 mm or 1/4" OD tube SS compression fitting Drain hose: 19 x 25.4 mm (¾ x 1"), 2 m (6 ft) length included |
| Protection Rating | IP55 |
| Ingress Protection | IP55 (Enclosure) IP66 / NEMA4X (Electronics) |
| Silica Measurement Accuracy | ± 5 % of reading or ± 1 ppb, whichever is greater |
| Operator Interface | Simultaneous display of silica concentration and measurement or auto-cal status TFT color touchscreen |
| Zero calibration | Automatic, every measurement cycle |
| Analog Output | Powered 0 / 4 – 20 mA, 22 mA alarm, 500 ohm max load, not for use with externally powered circuit |
| Analog Output Scaling | Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging |
| Power Supply | 100 – 240 VAC, 50 – 60 Hz, 100 W on power loss all settings are retained without batteries |
| Power Supply (AC/DC) | 100 V – 240 V |
| Flow Rate | 50 mL/min – 250 mL/min |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Digital Input |
|---|
| Remote start / stop of measurement cycle |
| Measurement Parameter | Silica |
|---|
| Reagent Consumption | Approx 500 mL each per 3 months with 20 min measurement cycle time |
|---|
| Humidity | 10 – 90 % non-condensing |
|---|
| Communication | PROFIBUS DP |
|---|
| Grab Sample Measurement | 500 mL capacity |
|---|
| Sample Pressure | 0.3 – 7 bar (5 – 100 psig) |
|---|
| Analog Output Accuracy | ± 0.05 mA |
|---|
| Measurement Cycle Time | 20 min typical Adjustable ≥ 10 min |
|---|
| Weight | 18 kg (40 lbs) |
|---|
| Sample Temperature | 5 – 60 °C (41 – 140 °F) |
|---|
| Model Family | 2850Si |
|---|
| EnclosureType | Full |
|---|
| Dimensions HWD | Enclosure: 543 x 413 x 300 mm (21.4" x 16.3" x 11.8") |
|---|
| Outputs | 8 Powered 0 / 4 – 20 mA |
|---|
| Relay Contact(s) | 4-SPST Type Reed 250 VAC or DC, 0.5 A 4-SPST mechanical rated at 250 VAC, 3 A |
|---|
| Resolution | 4 digits with decimal, autoranging 0.001 ppb in lowest range |
|---|
| Built-in sequencer | Yes |
|---|
| Ambient Operating Temperature | 10 – 50 °C (50 – 122 °F) |
|---|
| Ratings/Approvals | CE, cULus |
|---|
| Span calibration | Automatic per schedule once per month, typical |
|---|