| Agency Method|MultiLine | USP 467 |
|---|---|
| Capillary Tubing | Fused Silica |
| Film Thickness | 3 µm |
| Format | 7 inch |
| GC Column Type | Ultra Inert |
| Inner Diameter (ID) | 0.53 mm |
| Length | 30 m |
| Phase | DB-624 Ultra Inert |
| Polarity | Mid Polarity |
| Temperature Range | 40 °C-260/260 °C |
| UNSPSC Code | 41115710 |
| USP Designation | G43 |
| With Smart Key | No |
Answer:It is 30 m × 0.53 mm with a 3.0 µm stationary-phase film.
Answer:It is designed for USP <467> residual-solvent analysis and uses a USP G43 phase.
Answer:The stated upper temperature limit is 260 °C.
J&W DB-Select 624 Ultra Inert GC Column, for United States Pharmacopeia Residual Solvent Method 467, 30 m, 0.53 mm, 3.0 μm, 7 inch cage is designed for gas-chromatographic analysis of residual solvents under USP using an ultra-inert DB-624 stationary phase. This fused-silica capillary measures 30 m in length and 0.53 mm in internal diameter, with a 3.0 µm stationary-phase film and a standard seven-inch cage. Its DB-Select 624 Ultra Inert chemistry has medium polarity and USP G43 classification, providing selectivity suited to residual-solvent separations. The stated temperature range is 40 °C to 260 °C, with a 260 °C upper isothermal and programmed-temperature limit for this configuration. Ultra-inert construction is intended to reduce unwanted interactions during trace-level solvent analysis, while the relatively thick film supports retention of volatile analytes. The 0.53 mm bore provides a defined wide-bore format for compatible GC instruments. This column format fits common Agilent 5890, 6890, 7820, 7890, 8860 and 8890 series ovens, as well as other GC systems with an equivalent oven configuration. It is intended for GC method development and testing of residual organic solvents, not for HPLC, ion chromatography or sample extraction. The fused-silica construction and medium-polarity phase give a distinct GC separation mechanism from reversed-phase liquid chromatography. The seven-inch cage is an instrument-oven hardware format, not a difference in the stationary-phase chemistry. The format is supplied as a single capillary column for installation in a compatible gas chromatograph.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.