| Application Area | Connections |
|---|---|
| Process Step | Drug Product Final Filling; Media Preparation; Buffer Preparation; Drug Substance Purification; Cell Harvest & Downstream Processing Intermediates |
| Connection Method | Automated Connection; Tube Welding |
|---|---|
| Connection Time | 1.5 – 2.5 minutes depending on tube size and quality |
| Connections | Tube Welding |
| Connector Gender | Female; Male |
| Dimensions WxDxH | 555 × 261 × 69 mm |
|---|---|
| Tube Size (ID – OD) | 1/8" × 1/4" (3.2 mm × 6.4 mm); 1/4" × 3/8" (6.4 mm × 9.6 mm); 1/4" × 7/16" (6.4 mm × 11.1 mm); 3/8" × 5/8" (9.6 mm × 15.9 mm); 1/2" × 3/4" (12.7 mm × 19.1 mm); 5/8" × 7/8" (15.9 mm x 22.22 mm); 3/4" × 1" (19.1 mm × 25.4 mm) |
| Tubing | Refer to the datasheet |
|---|
| Tubing Material | Synthetic Thermoplastic Elastomer |
|---|
Answer:It automatically creates sterile connections between compatible thermoplastic tubing.
Answer:Yes. The system can weld compatible dry or liquid-filled TPE tubing.
Answer:Connection time is approximately 1.5–2.5 minutes depending on tubing size and quality.
Biowelder® Total Containment is an automated system for sterile connection of compatible thermoplastic tubing in bioprocess and cell-processing workflows. The welder can join dry or liquid-filled TPE tubing and supports outer diameters up to 1 inch across several validated ID/OD combinations. A typical weld takes approximately 1.5–2.5 minutes depending on tubing size and material. The closed welding process is used for media preparation, buffer preparation, cell harvest, downstream intermediates, purification, and final-filling workflows where maintaining a closed fluid path is important. The instrument operates from a 100–240 V, 47–63 Hz power supply. Using automated tube welding can replace manual open connections and reduce the number of conventional fittings required in single-use process assemblies.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Relative Humidity | 80 % up to 31 °C, linearly diminishing to 50 % relative humidity at 40 °C |
|---|
| Power Requirements | 100 - 240 V | 47 - 63 Hz |
|---|
| Brand | Biowelder® TC |
|---|---|
| Pack Size | 1 |
| Delivery Condition | Non-Sterile |
|---|