| Description | Ag |
|---|---|
| Diameter (Metric) Outer | 9 mm |
| For Use With (Application) | Sample Pretreatment and Removal of Chloride, Bromide, and Iodide from Concentrated Sample Matrices |
| Length (Metric) | 24 mm |
| Material | Styrene-Based Sulfonic Acid Resin in the Silver Form |
| Quantity | Each 1 |
| Product Line | InGuard |
| Type | InGuard Ag Cartridge |
| Unit Size | Each 1 |
Answer:It removes chloride, bromide and iodide from concentrated sample matrices.
Answer:It uses a styrene-based sulfonic-acid resin in the silver form.
Answer:It is installed in line between the autosampler and the ion-chromatography injection valve.
Dionex™ InGuard™ Ag Cartridges is designed for in-line pretreatment of high-ionic-strength samples before ion chromatography. The 24 mm cartridge contains a styrene-based sulfonic-acid resin in the silver form. Silver ions on the resin remove halide interferences including chloride, bromide and iodide from concentrated sample matrices such as brines, helping prevent large matrix components from overwhelming or interfering with the downstream IC separation. The cartridge is installed between the autosampler and the ion-chromatography injection valve so sample cleanup occurs automatically as the sample travels toward the analytical system. This in-line position removes the need for a separate manual sample-treatment step and improves consistency when many similar high-salt samples must be processed. The silver-form resin is selected specifically for precipitation or retention of halide ions, while the styrene-based support provides the physical cartridge medium. This format is used as a sample-preparation device rather than as the primary analytical separation column. It is useful in applications where concentrated chloride, bromide or iodide would otherwise produce large peaks, suppress target analytes or increase contamination of the analytical column and suppressor. The cartridge is especially useful when chloride-rich samples must be analyzed for other ionic components because it lowers a dominant halide load before injection. Integrating pretreatment into the autosampler flow path also reduces operator-to-operator variation compared with separate manual treatment steps.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.