Description
Volume (Metric): 5 mL
Unit Size: Each
These pre-packed columns are ready to connect and have the following features:
• Dimensions of 1 mL (0.8 x 2 cm) and 5 mL (0.8 x 10 cm)
• Direct connection to standard chromatography systems
• Packed with CaptureSelect CH1-XL Affinity Matrix, offering high dynamic binding capacity and high resolution over a wide range of flow ratesThe 1 mL columns can be used for quick screenings of application feasibility and lab scale purification on a convenient and easy-to-use pre-packed column. The 10 cm bed height of the 5 mL columns allows initial process development on a bench scale.The CaptureSelect CH1-XL Affinity Matrix recognizes the CH1 domain of human IgG antibodies, thereby enabling purification of all Fab fragments, independent of the light-chain type (kappa or lambda) and without binding of over-expressed light chain and light-chain dimers. In addition, it can be used for the purification of human IgGs from all four subclasses (1, 2, 3, and 4).Features of this affinity matrix include:
• Platform approach for purification of high quality and correctly assembled human Fab fragments
• No co-purification of over-expressed free light chains due to selectivity for the CH1 domain
• Elution possible at pH 4.0–4.5 with 50 mM acetate buffer
• Caustic cleaning with up to 50 mM NaOH
• Excellent scalability
• No cross binding to bovine IgG, therefore presence of fetal bovine serum is not a problemFree of animal componentsCaptureSelect products contain affinity ligands based on recombinant single-domain antibody fragments (VHH) created by a proprietary technology. The VHH affinity ligand is a 12 to 15 kDa fragment comprising the three complementarity-determining regions (CDRs) that form the antigen-binding domain, efficiently produced in the yeast Saccharomyces cerevisiae by a production process free of any animal components (Animal Origin-Free).Main characteristics:
• Matrix:agarose-based, epoxide-activated
• Average particle size:65 ± 10 μm
• Ligand:CaptureSelect CH1-XL affinity ligand
• Ligand coupling method:epoxide coupling
• Binding capacity:>15 mg/mL human Fab fragment, depending on flow rate, column height, and contact time. Note that humanized Fab fragments may have lower capacities.
• Elution conditions:100 mM glycine buffer, pH 3.0; 50 mM acetate buffer, pH 4.0 - 4.5
• Column dimensions:1 mL (0.8 x 2 cm) and 5 mL (0.8 x 10 cm)
• Flow characteristics:75–150 cm/h (up to 2 bar)
• Formulation buffer:20%(v/v) ethanol