Description
Unit Size: Each
Fluke T5 Voltage, Continuity and Current Testers.
• Automatically measures volts AC and volts DC with precise digital resolution.
• Displays resistance to 1000 Ω.
• Easy and accurate OpenJaw™ current measurement.
• Continuity beeper.
• Rugged enough to withstand a 10 ft (3 m) drop.
• 600 V model.
• Auto off mode to conserve battery life.
• AC current.
• Display hold.
• All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.Fluke 62 MAX+. Small in size. Big on toughness.
• Dust and water-resistant: IP54 rated.
• Rugged: 3 m (9.8 ft) drop tested.
• Ergonomically designed: Completely redesigned for a more natural hand fit.
• Distance to spot: 12:1.
• Dual lasers: Identifies area to be measured.
• Large, backlit display: Makes data easier to read, even in dark areas.
• C115 Deluxe soft carrying case with shoulder strap.This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.Fluke T5-600 Voltage, Continuity and Current Tester
• Specifications
• Jaw opening: 12.9 mm (0.5 in)
• Max wire size: 1/0 THHN cable
• Current range AC rms: 0 to 100.0 A
• Accuracy AC current (50/60 Hz): 3% ± 3 counts
• AC Response: Averaging
• Voltage range AC: 0 to 600 V
• Accuracy AC voltage: 1.5% ± 2 counts
• Voltage range DC: 0 to 600 V
• Accuracy DC voltage: 1% ± 1 count
• Resistance range: 0 to 1000 Ω
• Continuity beeper threshold: On at < 25 Ω, off at > 400 Ω
• Volts indicator LED threshold: Guaranteed on by 30 V ACEnvironmental Specifications
• Operating temperature: -10°C to 50°C
• Storage temperature: -30°C to 60°C
• Humidity (without condensation):0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C);0% to 45% (40°C to 50°C)
• Dust/water resistance: Yes
• Operating altitude: 2000 meters max
• Temperature coefficient: 0.1 x (specified accuracy)/°C (< 18°C or > 28°C)Safety Specifications
• Measurement Category: IEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac
• Agency approvals: CSA, TUV
• Maximum voltage: 600 V between any terminal and earth groundMechanical and General Specifications
• Size: 30.5 x 51 x 203 mm
• Weight: 300 g
• Warranty: Two-years
• Battery life: 200 hour zinc chloride, 400 hour alkaline
• Battery type: 2 x AA
• Low battery indicator: Yes
• Current sensor opening: 12.9 mm
• Calibration cycle: 1 year
• Test leads
• Type:Heavy duty, flexible leads rated for 1000 V use.Field replaceable leads terminate in male shrouded banana plugs
• Probes:One red, one black.Detachable Slim-Reach™ probe tips
• Styles: TP1 Slim Reach™ test brobesSafety Specifications
• Safety: CAT IV 600 V, CAT III, 1000 V
• Maximum voltage: 1000 V AC rms from earth to ground, in compliance with EN61010Fluke 62 MAX+ Infrared Thermometer
• Specifications
• Temperature range: -30°C to 650°C (-22°F to 1202°F)
• Accuracy:±1.0°C or ±1.0% of reading, whichever is greater-10°C to 0°C: ±2.0-30°C to -10°C: ±3.0
• Response time:(95%) < 300 ms (95% of reading)
• Spectral response 8 to 14 microns
• Emissivity 0.10 to 1.00
• Optical resolution: 12:1 (calculated at 90% energy)
• Display resolution: 0.1°C (0.2°F)
• Repeatability of readings: ±0.5% of reading or < ±0.5°C (1°F), whichever is greater
• Power: AA battery
• Battery life: 8 hours with laser and backlight onPhysical Specifications
• Weight: 255 g (8.99 oz)
• Size: 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
• Operating temperature: 0°C to 50°C (32°F to 122°F)
• Storage temperature: -20°C to 60°C (-4°F to 140°F), (without battery)
• Operating humidity: 10% to 90% RH non-condensing at 30°C (86°F)
• Operating altitude: 2000 meters above mean sea level
• Storage altitude: 12,000 meters above mean sea level
• IP rating: IP 54 per IEC 60529
• Drop test: 3 meters