Description
Battery Life: 2 Years, continuous operation
Unit Size: Each
Honeywell BW™ Clip4When you’ve got your hands full in the field, you need no hassle gas detection you can count on: the Honeywell BW™ Clip4 four-gas detector. Wearable, easy multi-gas detection that’s always on. No charging, no battery replacement, no hassle. Simpler, low cost of ownership guaranteed by the Honeywell commitment to quality, and backed by a full ecosystem of supporting technologies. When you clip on the Honeywell BW™ Clip4 you know – it’s on.Always On: 2-Year Continuous Runtime.Once activated, you can rest assured that the Honeywell BW™ Clip4 is always on. The Honeywell BW™ Clip4 is easy to wear and use. Lower your maintenance costs with two years of continuous runtime without charging and no battery or sensor replacements. Simply turn your new detector on and then after two years replace it for a new one.Features & Benefits
• 2 year continuous runtime. It's always on
• Simple one-button operation
• Low cost of ownership.Quick Specs
• H2S, CO, LEL, O2
• No hassle. No charging. No sensor/battery replacements
• IntelliDoX compatibleTechnical Specifications
• Size: 12.0 x 6.8 x 3.2 cm / 4.7 x 2.7 x 1.3 in.
• Weight: 233 g / 8.2 oz.
• Operating Temperature: -20 to +50°C / -4 to +131°F
• Humidity: 5 - 95% RH (non-condensing) continuous
• Ingress Protection: IP68
• Alarms and Type: Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit)
• Self-test: Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry).
• Typical Battery Life: Two years, continous operation
• Event Logging: 70 most recent eventsUser Options
• Adjust STEL period (5-15 minutes in 1 minute intervals)
• Calibration span levels
• Calibration interval
• Bump test interval
• Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v
• Calibration due date (1 to 365 days, or set to zero for off)
• Individual sensor enable/disable
• Latching alarms
• Stealth modeCertifications and Approvals
• Class I, Div 1, Group A, B, C, D
• Class I, Zone 0, Group IIC
• ATEX: II 1G Ex ia IIC T4 Ga
• IECEx: Ex ia IIC T4 Ga
• CE: Conforms to all applicable European directives.Sensor SpecificationsGases
• Hydrogen Sulfide (H2S): 0 - 100 ppm 1 / 0.1 ppm
• Carbon Monoxide (CO): 0 - 1,000 ppm 1 ppm
• Oxygen (O2): 0 - 25% vol. 0.1% vol.
• Combustible Gases (LEL)*: 0 - 100% LEL 1% LEL*Caution – the LED IR combustible gas sensor used in Honeywell BW™ Clip4 cannot detect certain combustible gases including hydrogen and acetylene. The application should be reviewed to ensure the Honeywell BW™ Clip4 can provide adequate detection.Item number: BWC4-Y-ABW Clip4 4-gas detector (O2, LEL, H2S, CO), Australia version - yellow housing