Description
Length (Metric): 60 cm
No. per Pack: 1 Ea.
Unit Size: Each
Fluke i3000 FLEX AC Current ProbeThe i3000s Flex is an AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.Key Features:
• Three ranges, 30 A, 300 A, 3000 A, 1, 10 or 100 mV/A output
• Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
• Maximum conductor diameter 178 mm (7 in)
• CAT III 600 V safety rating
• One year warrantyElectrical Specifications:
• Current ranges:30 A300 A3000 AAC rms
• Output sensitivity (AC-coupled):100 mV10 m1 mV per A
• Load impedance: 100 kΩ minimum
• Accuracy:at +25°C±1% of range (45 Hz to 65 Hz)
• Linearity:10% to 100% of range±0.2% of reading
• Noise:8 mV AC rms (30 A)2 mV AC rms (300 A, 3000 A)
• Frequency range: 10 Hz to 50 kHz (-3 dB)
• Phase error:< ±1° (45 Hz to 65 Hz)±10° (at 20 kHz)
• Position sensitivity:with cable > 25 mm from the coupling±2% of range
• External field:with cable > 200 mm from the head±1% of range
• Power supply: 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply
• Temperature coefficient:±0.08% of reading per°CWorking voltage see safety standards section600 V AC rms or DCGeneral Specifications:
• Head circumference: 610 mm (24in)
• Head cable diameter: 14.3 mm (0.56in)
• Head bend radius: 38.1 mm (1.5in)
• Cable length (head to electronics): 2 m (6.56 ft)
• Output connection: 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
• Operating temperature range:-20°C to +90°C (-4°F to 190°F) (head)-20°C to +85°C (-4°F to 185°F) (electronics)
• Strong temperature range:-40°C to +105°C (-40°F to 221°F) (head)-20°C to +85°C (-4°F to 185°F) (electronics)
• Operating humidity:15% to 85% (non-condensing)
• Weight:180 g (0.396 lb) (head)190 g (0.419 lb) (electronics)
• Safety standards:BS EN 61010-1: 2001BS EN 61010-2-032: 2002BS EN 61010-031: 2002
• 600 Vrms, Category III, Pollution Degree 2
• Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
• EMC standards EN 61326: 1998 +A1, A2, and A3
• Head cable length (double insulated): 610 mm or 914 mm, depending on model