| Chemistry | C18 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Silica |
| pH Range Min | 3 pH |
| pH Range Max | 7 pH |
| Maximum Pressure | 6000 psi (415 Bar) |
| Endcapped | Yes |
| Bonding Technology | dC18 |
| Silanol Activity | Medium |
| Particle Shape | Spherical |
| Particle Size | 3 µm |
| Endfitting Type | Waters |
| Pore Size | 100 Å |
| Format | Column |
| Surface Area | 330 |
| System | HPLC |
| USP Classification | L1 |
| Inner Diameter | 4.6 mm |
| Length | 150 mm |
| Carbon Load | 12 % |
| UNSPSC | 41115709 |
| Brand | Atlantis |
| Product Type | Columns |
| Units per Package | 1 pk |
Answer:It is designed to improve reversed-phase retention of polar compounds while also supporting standard non-polar separations.
Answer:Yes. The dC18 chemistry is optimized for highly aqueous conditions, including 100% water.
Answer:The column is 4.6 mm ID × 150 mm with 3 µm, 100 Å particles, a pH range of 3–7, and a maximum pressure of 6000 psi (415 bar).
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pk is used for reversed-phase HPLC separations that need stronger retention of polar compounds while remaining compatible with highly aqueous mobile phases. The column uses a silica substrate with difunctionally bonded dC18 ligands and an endcapped surface. Its 3 µm spherical particles have a 100 Å pore size, and the phase carries a 12% carbon load. The 4.6 mm inner diameter × 150 mm format supports conventional analytical HPLC, with a maximum pressure of 6000 psi (415 bar) and a pH range of 3–7. The dC18 chemistry is optimized for aqueous conditions, including operation with 100% water, and is designed to resist dewetting while improving retention of polar analytes compared with conventional reversed-phase materials. This makes it useful for methods that must retain both polar and non-polar compounds without moving to a different separation mode. The 3 µm particle size provides a higher-efficiency format than standard 5 µm columns while preserving familiar 4.6 mm HPLC dimensions for routine method development and analytical testing.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.