| Chemistry | C4 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Hybrid |
| pH Range Min | 1 pH |
| pH Range Max | 10 pH |
| Maximum Pressure | 6000 psi (415 Bar) |
| Endcapped | No |
| Silanol Activity | Low |
| Molecular Weight Range Max | 150000 |
| Particle Shape | Spherical |
| Particle Size | 3.5 µm |
| Pore Size | 300 Å |
| QC Tested | Protein |
| Format | Sentry Guard Cartridge |
| Surface Area | 185 |
| System | HPLC |
| Particle Technology | BEH |
| USP Classification | L26 |
| Inner Diameter | 4.6 mm |
| Length | 20 mm |
| Carbon Load | 8 % |
| UNSPSC | 41115709 |
| Application | Protein |
| Brand | XBridge |
| Product Type | Guards |
| Units per Package | 2 pk |
Answer:The BEH C4 guard packing has 300 Å pores and 3.5 µm particles in a 4.6 × 20 mm cartridge.
Answer:Two Sentry guard cartridges are supplied.
Answer:No. A compatible Sentry holder is required; the universal Waters holder is a separate product.
Waters XBridge Protein BEH C4 Sentry Guard Cartridges are reversed-phase guard beds for protecting protein analysis columns against sample-derived contaminants. Each cartridge contains 3.5 µm hybrid-particle C4 packing with 300 Å pores in a 4.6 mm internal diameter by 20 mm long format. The pack contains two cartridges. The relatively short-chain C4 chemistry is less hydrophobic than C18 and is useful in methods that require protein recovery with controlled retention. The wide-pore packing supports interaction with proteins and larger biomolecules, while the replaceable guard bed intercepts contaminants before the analytical column. These Sentry cartridges require a compatible holder; the Waters universal holder is ordered separately. When replacing the guard, verify both the holder dimensions and the analytical column chemistry, then monitor backpressure and chromatographic behavior. The cartridge is not a full-length analytical column and cannot substitute for the column's separation bed.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.