Biolegend, 427201, Veri-Cells™ Heavy Metal (Ta) PBMC
10tests
Catalog Number: 427201
Send an RFQ.
Category
Pack Size2 vials
| Formulation | Cat. No. 427201: 2 vials each containing ≥ 1 X 106 lyophilized human peripheral blood mononuclear cells (PBMC).Cat. No. 427203: 10 vials each containing ≥ 1 X 106 lyophilized human peripheral blood mononuclear cells (PBMC). |
|---|---|
| Preparation | The Veri-Cells™ Heavy Metal Ta PBMC kit is prepared from 2 vials of lyophilized human PBMCs labeled with tantalum and a vial of Veri-Cells™ Buffer A Plus. |
| Storage & Handling | Store the kit at 2°C - 8°C upon receipt. Do not open sealed pouch until ready to use. Once reconstituted, the cells may be used for up to five days if properly stored at 2°C - 8°C in the buffer provided. |
| Application | FC, CyTOF® - Quality tested |
| Recommended Usage | 50 µL per test (after reconstitution with 325 µL of Veri-Cells™ Buffer A Plus) Once reconstituted, let the cells sit for 15 minutes at room temperature prior to staining. Veri-Cells™ Buffer A Plus may show precipitation over time, however this is normal and does not affect performance of the buffer. |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Application Notes |
|---|
| The Veri-Cells™ Heavy Metal Ta PBMC kit contains stabilized human blood cells which have been pre-labeled with the metal tantalum (Ta). The reconstituted human PBMCs can be added to test samples as a control for CyTOF applications. The cells have been verified to work with commonly tested cell markers such as CD3, CD4, CD8, CD14, CD16, CD19, CD38, CD56, CD123 and HLA-DR. Assessing the suitability of this product as a control for the end user’s molecule of interest is recommended. The tantalum signal is confirmed by a CyTOF Helios or equivalent mass cytometry instrument. Cell subset Acceptance Criteria, % positive of lymphocyte gate CD3+ 55-95 CD4+CD3+ 30-65 CD8+CD3+ 10-40 CD19+CD3 – 3-30 CD56+CD16+CD3 – 3-40 Note on indicated ranges: Percent positive values are obtained based on gates set on unstained cells. The antibodies used for testing were the following: CD56 PE (clone 5.1H11), CD16 PE (clone 3G8), CD19 APC (clone HIB19), CD3 FITC (clone UCHT1), CD4 PE/Cyanine7 (clone RPA-T4), and CD8 APC/Cyanine7 (clone RPA-T8). Variability in antibodies used, instruments, staining conditions and other factors may influence end-user values. The Certificate of Analysis specific values are provided as a reference. It is recommended that individual laboratories establish its own control values and ranges for each parameter based on laboratory specific conditions and protocols. Please use our CoA Look-Up Tool to find the expected lot-specific frequencies of certain cell populations included within each lot of Veri-Cells™ Heavy Metal (Ta) PBMC. |
| Additional Product Notes | Veri-Cells™ Buffer A Plus is an improved version of the original Veri-Cells™ Buffer A to improve staining performance with tandem dyes. |
|---|
| Product Citations | Diray-Arce J, et al. 2023. Cell Rep Med. 4:101079. PubMed Lee HJ, et al. 2023. iScience. 108387:26. PubMed |
|---|
| Gene ID | NA |
|---|
| Regulatory Status | RUO |
|---|
| Other Names | Control cells |
|---|