| Column Capacity | 20 μeq |
|---|---|
| Flow Rate | 1.0 mL/min. |
| For Use With (Application) | Carbohydrate Analysis |
| For Use With (Equipment) | HPAE-PAD |
| Green Features | FSC |
| Max. Pressure | 4000 psi (275 bar) |
| Particle Size | 10 μm |
| Quantity | Each 1 |
| Solvent Compatibility | pH 0 to 14, Up to 90% of Common HPLC Solvents |
| Stationary Phase | CarboPac PA10 |
| Column Type | Guard Column |
| Diameter (Metric) | 4 mm |
| Format | Standard Bore |
| Length (Metric) | 50 mm |
| Unit Size | Each 1 |
Answer:No. This is the 4 mm × 50 mm guard column designed to protect a matching PA10 analytical column.
Answer:The guard-column capacity is 20 µeq.
Answer:It supports PA10 carbohydrate separations using high-performance anion exchange with pulsed amperometric detection.
Dionex™ CarboPac™ PA10 IC Columns is designed for protecting a CarboPac PA10 analytical column during high-performance anion-exchange chromatography of carbohydrates. This exact configuration is a 4 mm × 50 mm guard column, not the 250 mm analytical column in the same family. Its PA10 packing uses 10 µm nonporous polymer beads bearing functionalized latex MicroBeads, providing a stationary-phase chemistry matched to PA10 carbohydrate separation. Installed upstream of the analytical column, the guard intercepts sample contamination and strongly retained material before these reach the longer separation bed. The chemistry is useful in carbohydrate workflows involving mono- and disaccharides from foods, pharmaceuticals, plants and glycoprotein hydrolysates. Combined with pulsed amperometric detection, the PA10 separation system can detect these analytes without chemical derivatization. This guard format has a 20 µeq column capacity, a stated 1.0 mL/min flow rate and a 4000 psi (275 bar) maximum pressure. It is compatible with mobile-phase conditions from pH 0 to 14 and up to 90% of common HPLC solvents. The 50 mm length and matching 4 mm bore allow guard protection without substituting a full-length analytical bed. The matching PA10 stationary phase helps preserve the analytical method's intended selectivity while the guard column carries the contamination burden. Replace the guard when its performance deteriorates instead of treating it as a standalone 250 mm analytical column.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.