| Anion Exchange Capacity | 16 μeq |
|---|---|
| Certifications/Compliance | U.S. EPA Method 300.0 (A) |
| Column Capacity | 16 μeq |
| Column Chemistry | Carbonate/Bicarbonate |
| Column Construction | PEEK |
| Crosslinking | 55% DVB |
| Flow Rate | 0.3 to 0.75 mL/min. |
| For Use With (Application) | Analysis of Fluorides and Other Inorganic Anions |
| For Use With (Equipment) | ASRS 300 System |
| Green Features | FSC |
| Hydrophobicity | Medium-High |
| Ion Exchange Group | Alkyl Quaternary Ammonium |
| Max. Pressure | 4000 psi (275 bar) |
| Packing Material | Ethylvinylbenzene/Divinylbenzene |
| Particle Size | 9 μm |
| Pore Size | 100 Å |
| Quantity | Each 1 |
| Solvent Compatibility | pH 2 to 12, 0 to 100% HPLC Solvents |
| Stationary Phase | IonPac AS14 |
| Column Type | Analytical Column |
| Diameter (Metric) | 2 mm |
| Format | Microbore |
| Length (Metric) | 250 mm |
| pH | 2 to 12 |
| Unit Size |
Answer:This is a 2 mm × 250 mm analytical ion chromatography column.
Answer:It is the analytical separation column.
Answer:The AS14 chemistry uses carbonate/bicarbonate eluent for isocratic anion separations.
Dionex™ IonPac™ AS14 IC Columns is designed for isocratic anion chromatography of common inorganic anions in environmental and other aqueous samples. This configuration is the 2 mm × 250 mm analytical column, not the shorter guard version. Its medium-capacity anion-exchange phase separates anions with a carbonate/bicarbonate eluent, allowing a straightforward isocratic workflow without the hydroxide-gradient setup used by some alternative ion chromatography phases. AS14 chemistry is suited to separating fluoride and other inorganic ions and offers improved fluoride retention and resolution relative to certain earlier IonPac phases. The long analytical bed provides the chromatographic separation, while a matching 2 mm AS14 guard can be used upstream to help protect it from sample contamination. Its 2 mm bore supports the corresponding small-bore IC configuration and should be matched to appropriate flow, suppressor and system hardware for the method. This configuration provides analytical separation in a defined 250 mm column rather than the protective function of the 50 mm guard. It is intended for laboratory anion measurements under established AS14 carbonate-eluent methods.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Each 1 |