| Column Construction | PEEK |
|---|---|
| Description | AminoTrap; 3 x 30 mm |
| For Use With (Application) | Retention of Amino Acids from Carbohydrate Samples |
| For Use With (Equipment) | HPAE-PAD |
| Green Features | FSC |
| Max. Pressure | 3000 psi (207 bar) |
| Particle Size | 6.5 μm |
| Quantity | Each |
| Resin Composition | 6.5 μm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 130 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked). |
| Solvent Compatibility | 100% Compatible with Common HPLC Solvents and 100% Water |
| Stationary Phase | CarboPac PA20 |
| Temperature (Metric) | 4°C to 60°C |
| Column Type | Trap Column |
| Diameter (Metric) | 3 mm |
| Format | Microbore |
| Length (Metric) | 30 mm |
| pH | 0 to 14 |
| Unit Size | Each |
Answer:It retains interfering amino acids during monosaccharide analysis so they do not interfere with the carbohydrate separation.
Answer:It is installed in-line before a compatible carbohydrate analytical column, in place of a conventional guard column.
Answer:The 3 × 30 mm PEEK trap column supports pH 0–14, temperatures from 4–60 °C, and pressures up to 3000 psi (207 bar).
Dionex™ AminoTrap™ Column, 3 x 30 mm is used as an in-line pretreatment trap for monosaccharide analysis by HPAE-PAD, retaining interfering amino acids until the monosaccharides have eluted. The 3 mm ID × 30 mm microbore column is installed before a compatible carbohydrate analytical column and can be used with the Dionex CarboPac PA20 format. This configuration is useful for samples such as glycoprotein hydrolysates or food-derived samples that contain amino acids such as lysine, because the trap reduces amino-acid interference and helps limit fouling of the working electrode. The column uses PEEK construction, supports pH 0–14, and is rated to 3000 psi (207 bar), with an operating temperature range of 4–60 °C. Its resin uses a crosslinked ethylvinylbenzene/divinylbenzene substrate with quaternary-ammonium functionality and is compatible with common HPLC solvents and water. The compact 3 × 30 mm format is specifically intended as a trap column rather than a primary analytical separation column.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.