| Accuracy | ±5% or 0.01ppb – whichever is greater |
|---|---|
| Description | Low Level Sodium Consumables Kit - for one year operation |
| Flow Rate | 40 mL/min. |
| For Use With (Equipment) | Orion™ 2111LL Low Level Sodium Analyzers |
| Frequency | 50/60 Hz |
| Includes | 6 x 0.8L diisopropylamine (DIPA) reagent and 6 diffusion tubing kits (211191), reagent bottle adapter, sodium calibration standards kit with etch solution (181148), sodium electrode (210048), reference electrode (210058), 5 x 2 oz. reference filling solution (211172), O-ring kit (2111LLOK), check valve (2111VC), box of pipette tips (207525-001), restriction tube assembly and 2 x 60 micron inlet filters with gaskets (181170) |
| Inlet Pressure | 8 to 100psig |
| Max. Relative Humidity | 211192 |
| Outputs | 211192 |
| Range | 0.001-10 ppb-ppm |
| Resolution | 1; 2; 3; or 4 significant digits |
| Response Time | 95% within 2 minutes |
| Sample Temperature | 5 to 45 °C |
| Voltage | 85/132 V (100 mA), 170/264 V (200 mA) |
| Weight (English) | 50 lb. |
| Weight (Metric) | 22.7 g |
| Temperature (Metric) Operating |
Answer:It is designed for the Orion 2111LL Low Level Sodium Analyzer.
Answer:The kit is configured as an annual consumables set for approximately one year of operation.
Answer:Yes. It includes six 0.8 L bottles of diisopropylamine reagent together with diffusion-tubing and other maintenance consumables.
The Orion™ 2111LL Sodium Consumables Kit provides the routine reagents, electrodes, tubing, standards, seals, and small fluid-path components required for approximately one year of operation of the Orion 2111LL low-level sodium analyzer. The kit includes six 0.8 L bottles of diisopropylamine reagent, six diffusion-tubing kits, a reagent-bottle adapter, sodium calibration standards with etch solution, a sodium sensing half-cell, a reference electrode, five bottles of reference filling solution, an O-ring kit, a check valve, pipette tips, a restriction-tube assembly, and two 60 µm inlet filters with gaskets. Consolidating these items in one annual kit simplifies preventive maintenance and reduces the risk of running out of critical consumables during continuous low-level sodium monitoring. Use the components only with compatible 2111LL analyzer procedures and maintenance intervals.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| 5°C to 45°C |
| Type | Sodium Consumables Kit |
|---|
| Unit Size | Each |
|---|