Unit Size: Each
Fluke Amprobe 37XR-A True RMS, Auto-Ranging DMM With Component and Logic TestThe Amprobe 37XR-A Digital Multimeter offers true-rms measurement along with component and logic testing for troubleshooting electronics at the bench or on the job site.Features:
• Backlight, True-rms with component and logic test
• Inductance to 40 H, frequency to 40 MHz, capacitance to 400 μF, logic to 20 MHz
• Input warning tone when test leads are in the wrong jack
• 10 Amps AC/DC, fully safety fused
• Continuity beeper
• Min/max, average, relative, peak, and data hold
• Auto power off to save battery life
• Separate door for easy battery and fuse access
• Magne-Grip™ Holster with magnetic hanging strap
• Autoranging; display: 4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
• Display Update Rate: 2/sec, nominal
• Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
• Operating temperature: 0°C to 45°C at < 70 % R.HSpecifications:
• DC Voltage: 1.000 mV, 10.00 V, 100.0 V, 1000 V
• AC Voltage: 1.000 mV, 10.00 V, 100.0 V, 1000 V
• DC Current: 100.0 μA, 1.000 μA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A
• AC Current: 100.0 μA, 1.000 μA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A
• Resistance: 1000.0 O, 10.000 kO, 100.00 kO, 1000.0 kO, 10.00 MO , 40.00 MO
• Continuity:
• Diode:
• VolTect™ Non-Contact Voltage Detection:
• Capacitance: 40.00 nF. 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF
• Frequency: 100.00 Hz, 1.0000 kHz, 10.000 kHz, 100.00 kHz, 1.0000 MHz, 10.000 MHz
• Temperature:
• Duty cycle: 0.00 % → 90.0 %
• Logic test:
• Inductance: 40 H
• dBm: -13 dBm → + 50 dBm
• Specifications:
• DC Voltage ranges: 1000 mV, 10 V, 100 V, 1000 V
• DC Voltage accuracy: all ranges ± (0.1 % rdg + 5 dgt)
• DC Voltage resolution: 100 μV
• AC Voltage (45 Hz to 2 kHz) True-rms ranges: 1000 mV, 10 V, 100 V, 750 V
• AC Voltage (45 Hz to 2 kHz) True-rms accuracy: 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
• AC Voltage (45 Hz to 2 kHz) True-rms accuracy: All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts)
• AC Voltage (45 Hz to 2 kHz) True-rms accuracy: All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts)
• AC Voltage (45 Hz to 2 kHz) True-rms resolution: 100 μV
• AC coupled: True RMS specified from 5 % to 100 % of range
• DC Current ranges: 100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
• DC Current accuracy: 100 μA range: ± (0.5 % rdg + 10 dgt)
• DC Current accuracy: 1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts)
• DC Current accuracy: 10 A range: ± (1.5 % rdg + 10 dgt)
• DC Current resolution: 0.01 μA
• AC Current (45 Hz to 1 kHz) True-rms ranges: 100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
• AC Current (45 Hz to 1 kHz) True-rms accuracy: 100 μA to 100 mA ranges: ± (1.5 % rdg + 10 dgts)
• AC Current (45 Hz to 1 kHz) True-rms accuracy: 400 mA range: ± (2.0 % rdg + 10 dgts)
• AC Current (45 Hz to 1 kHz) True-rms accuracy: 10 A range: ± (2.5 % rdg + 10 dgts)
• AC Current (45 Hz to 1 kHz) True-rms resolution: 0.01 μA
• Resistance ranges: 1000 O 10 kO 100 kO 1000 kO 10 MO 40 MO
• Resistance accuracy: 1000 O to 1000 kO ranges: ± (0.5 % rdg + 8 dgts)
• Resistance accuracy: 10 MO range: ± (1.0 % rdg + 10 dgts)
• Resistance accuracy: 40 MO range: ± (2.0 % rdg + 10 dgts)
• Logic test, logic type: TTL, CMOS
• Warranty: 3 years