Description: RadEye GX Survey Meter
Unit Size: Each
RadEye GX Survey Meter for Geiger-Mueller Detectors
• Accepts a wide range of GM detectors
• Measurement range default (overrange indication starts at): 10,000 cps
• Measured quantities (requires individual probe calibration): Surface contamination (Bq, dps, dpm, Bq/cm^2), Dose rate (R/h, Sv/h, rem/h), Count rate (cps, cpm).
• High Voltage range: 350V…1100V.
• Output impedance: 1MOhm.RadEye SX Survey Meter for Scintillation Detectors
• Operates with dual phosphor α/β, NaI(Tl) and plastic probes.
• Measurement range default (overrange indication starts at):100,000 cps.
• Measured quantities (requires individual probe calibration): Count rate (cps, cpm), Surface contamination (Bq, dps, dpm, Bq/cm^2), Dose rate (R/h, Sv/h, rem/h).
• High Voltage range: 100 V ... 1400 V.
• Output impedance: 2MOhm.
• Thresholds: 4 (30 to 1280mV, 1mV resolution).
• Energy windows: 2 ROI (region of interest).RadEye PX Survey Meter for Proportional Detectors
• Operates with proportional detectors such as He-3 and BF3 neutron detectors.
• Measurement range default (overrange indication starts at): 100,000 cps.
• Measured quantities (requires individual probe calibration): Count rate (cps, cpm), Surface contamination (Bq, dps, dpm, Bq/cm^2), Dose rate (R/h, Sv/h, rem/h), Count rate (cps, cpm), Surface contamination (Bq, dps, dpm, Bq/cm^2).
• Dose rate (R/h, Sv/h, rem/h).
• High Voltage range: 100 V ... 2300 V.
• Output impedance: 2MOhm.
• Thresholds: 3 (30 to 1220mV, 1mV resolution).
• Energy windows: 1 ROI (region of interest).Features for all Survey Meters in the RadEye X Series:
• Connector Types MHV.
• Battery powered (2 x AAA alkaline or rechargeable), powered desktop station available as option.
• Alarms 80 dB at distance of 30cm (11.8 in.).
• Clear and large display.
• Versatile operation modes.
• Communication interface: Infrared (IR), optional IR to USB cable or IR to serial cable, optional Bluetooth™.
• Settings and data analysis done by optional Windows™ based PC-software via serial data connection, USB or Bluetooth.
• Logs last 250 alarms, error messages and changes of configuration.
• Background subtraction: in count rate and contamination mode.
• Probe library for 16 different detectors with data like high voltage, calibration factor, dead time correction, overload threshold, detector area and timeout for detector failure; Default values for common probes are preset.
• Internal memory: The last 1500 measured values are saved and can be read out via PC program; Max and mean value of count rate and dose rate; Time interval is factory preset to 120s by default; Scaler measurements and momentaneous readings stored manually.
• Averaging filters: Ratemeter filter type - Advanced Digital Filter (ADF), Digital RC-Filter with time constant, 1s to 180s, depending on count rate and count rate change.
• Certifications/Compliance EMC: Disturbance emission - EN 61000-6-3, immunity - EN 61000-6-2.View our online training here.