| Amperage | 15 A |
|---|---|
| Analysis Time | 30 to 140 min. (varies depending on run module) |
| Capillary Length | 50 cm, 36 cm |
| Dimensions (D x W x H) | Electrophoresis Unit Width (Closed Door): 61 cm, Electrophoresis Unit: 122 cm (W) (open door) x 61 cm (D) x 72 cm (H) |
| External Computer | Hard Drive: 2x 500GB SATA 3.0 Gb/s and 8 MB Data Burst Cache, Memory: 16 GB (2x 8GB) 1600 MHz DDR3 Non-ECC. 4th Gen Intel Core I7 Processor- 3.1 GHz Turbo Processor, Operating System: Windows 7 SP1 |
| For Use With (Equipment) | 3500 Genetic Analyzer |
| Format | 96-well plate, 8-well strips |
| Laser Features | Long-life single-line 505 nm solid-state laser excitation source., Long-life single-line 505 nm solid-state laser |
| Number of Capillaries | 8 Capillaries |
| Operating Environment | Humidity: 20%-80% (non-condensing), Room temp.: <2° fluctuation during runs, Room temp: <2° fluctuation during runs, Temperature: 15°C-30°C, Humidity: 20–80% (non-condensing) |
| Operating System | Windows 7 (Service Pack 1) |
| Polymer | POP-4™, POP-6™, POP-7™ |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Polymer Consumption |
|---|
| Replace at earliest of 14 days⁄96 samples⁄12 injections (96-sample pouches), Replace at earliest of 14 days⁄384 samples⁄60 Injections (384-sample pouches), Replace at earliest of 14 days⁄960 samples⁄120 Injections (960-sample pouches) |
| Quantity | 1 system |
|---|
| Read Length | ≥420 bp using a 36 cm capillary and POP-4™, >850 bp using a 50 cm capillary and POP-7™ polymer |
|---|
| Software | GeneMapper™ ID-X Software |
|---|
| Throughput | Range: 80 to 368 sequencing samples per day (varies depending on run module), ≥312 samples per day (HID36 POP4 Module), ≥ 312 samples/day (HID36_POP4), ≥88 samples per day (standard sequencing with POP to 7™ and 50 cm capillaries) |
|---|
| Voltage | Electrophoresis Voltage - Up to 20 kV |
|---|
| Warranty | 1 Year Limited Warranty on Parts and Labor, Service Installation and Application Training Included |
|---|
| Type | Genetic Analyzer |
|---|
| Unit Size | Each |
|---|