Thermo Fisher, 4440466, 3500 Genetic Analyzer for Resequencing
Quantity: 1 system, Unit Size: Each
Catalog Number: 4440466
Send an RFQ.
Category
| Amperage | 15 A |
|---|---|
| Capillary Length | 50 cm, 36 cm |
| Electrical Requirements | 100 V to 240 V, 50/60 HZ, 15 A |
| External Computer | Hard Drive: 2x 500GB SATA 3.0 Gb/s and 8 MB Data Burst Cache, Memory: 16 GB (2x 8GB) 1600 MHz DDR3 Non-ECC. 4th Gen Intel Core I7 Processor- 3.1 GHz Turbo Processor, Operating System: Windows 7 SP1, Hardware: Pentium™ IV Processor - 1.86 GHz Processor, Hard Drive: 1 x 80GB 7200 RPM SATA 3.0Gb⁄s and 8MB Data Burst Cache, Operating System: Windows™ Vista™ SP1, Installed RAM: 2GB |
| For Use With (Equipment) | 3500 Genetic Analyzer Capillary Array (50 cm), POP-6™ Polymer for 3500⁄3500xL Genetic Analyzers, POP-4™ Polymer for 3500⁄3500xL Genetic Analyzers, 3500 Genetic Analyzer Capillary Array (36 cm), POP-7™ Polymer for 3500⁄3500xL Genetic Analyzers |
| Format | 96-well Plate, 8-tube Strip |
| Height (English) Exterior | 28.34 in. |
| Height (Metric) Exterior | 72 cm |
| Length (English) Exterior | 24.01 in. |
| Length (Metric) Exterior | 61 cm |
| Max. Voltage | Electrophoresis Voltage - Up to 20 kV |
| Number of Capillaries | 8 Capillaries |
| Operating Environment |
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.
| Humidity: 20%-80% (non-condensing), Room temp: <2° fluctuation during runs, Temperature: 15°C-30°C |
| Operating System | Windows 7 (Service Pack 1) |
|---|
| Polymer | POP-4™, POP-6™, POP-7™ |
|---|
| Polymer Consumption | Replace at earliest of 7 days⁄384 samples⁄60 Injections (384-sample pouches), Replace at earliest of 7 days⁄960 samples⁄120 Injections (960-sample pouches) |
|---|
| Quantity | 1 system |
|---|
| Read Length | ≥850 bp using a 50 cm capillary and POP-7™ |
|---|
| Software Compatibility | Variant Reporter™ Software, GeneMapper™ Software |
|---|
| Throughput | Up to 368 samples per day (using run module ShortReadSeq POP7) |
|---|
| Warranty | 1 Year Limited Warranty on Parts and Labor, Service Installation and Application Training Included |
|---|
| Weight | 82 kg (approximately) |
|---|
| Width (English) Exterior | 24.01 in. |
|---|
| Width (Metric) Exterior | 61 cm |
|---|
| Software Type | Data Collection Software |
|---|
| Starting Material | DNA |
|---|
| Unit Size | Each |
|---|