Description
Unit Size: Each
Fluke 80I-110S AC/DC Current Probe, ScopemeterThe 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.Specifications
• Current Range: 0.1 to 100A DC or 0.1 to 70A AC
• Basic Accuracy (DC to 1kHz):100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading
• Output Signal: 10A range: 100mV/A ∣ 100A range: 10mV/A
• Bandwidth: 1Hz to 20kHz
• Working Voltage: 600V AC rms
• Maximum Conductor Size: 11.8 mm (.46 inch) diameter
• Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
• Nominal current range:10 A, AC/DC100 A, AC/DC
• Continuous current range:0.1 A - 10 A AC/DC1 A - 100 A AC/DC
• Maximum non-destructive current: 140 A - 2 kHz
• Lowest measurable current: 0.1 A
• Basic accuracy:100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA40 A to 80 A ±12% of reading +50 mA80 to 100 A ±15% of reading
• Useable frequency: DC - 100 kHz
• Output level(s):10 A range: 100 mV/A100 A range: 10 mV/A
• Zero error adjustment: YesSafety Specifications
• CAT II, 600 V
• CAT III, 300 V
• Maximum voltage: 600 VMechanical and General Specifications
• Battery life: 9 V, 55 h
• Maximum conductor diameter: 11.8 mm
• Output cable length: 1.6 m
• BNC adapter: Yes