Detector Type: Silicon Photodiode
Unit Size: Each
Carry AnywhereThe lightest, most compact portable spectrophotometer available easily goes where you need to go.Test What You NeedAnalyze your water with more preprogrammed methods than any other portable spectrophotometer, or easily create your own methods to suit your unique needs.Ensure Accuracy in the FieldWavelength range of 340 to 800 nm. provides accuracy typically seen only in laboratory instruments.Make Testing EasierSimple, easy-to-use interface plus the widest range of vial sizes makes testing flexible.Take Into Field EnvironmentsRugged construction keeps the elements out, which means you can test in the most demanding conditions.What's included?Includes: basic printed instrument manual, dust cover, 1-in. square matched glass sample cells, AA alkaline batteries 4/pk, and a four-type adapter set.SpecificationsBattery Life: 15 days (typical) @ 5 readings a day / 5 day week without backlight** Backlight usage will decrease battery life.Battery Requirements: 4, AA size alkali cellsCuvette Compatibility 2: 10 mm square / 1 inch square and13 mm / 16 mm / 1 inch roundData Logger: 500 measured values (Result, Date, Time, Sample ID, User ID acc. to GLP)Detector: Silicon photodiodeDisplay: Graphical display 240 x 160 pixel (LCD, b/w, backlit)Enclosure Rating: IP67Includes: Printed Basic Manual, CD with procedure manual (English) in pdf format. Set of vial adapter in carton box. Pkg of 4 AA Alkaline Battery. Dust CoverInterface: USB type Mini IP67 (with optional Module)Mains Connection 2: 110 - 240 V / 50/60 Hz (* optional Module required. May not be available in all regions)Mains Connection 3: 4x NiMH rechargeable Battery (* optional Module required. May not be avaliable in all region)Operating Conditions: 10 - 40 °C (50 - 104 °F), max. 80 % relative humidity (non-condensing)Operating Humidity: Max. 80 % relative humidity (non-condensing)Operating Mode: Transmittance (%), Absorbance and ConcentrationOperating Temperature: 10 - 40 °COptical System: Reference beam, spectralPhotometric Accuracy: ± 0.003 Abs @ 0.0 - 0.5 AbsPhotometric Linearity: < 0.5 % (0.5 - 2.0 Abs)Photometric Measuring Range: 0 - 3 Abs (wavelength range 340 - 800 nm)Power Module?: NoPower supply: 4 x AA size Alkaline4x NiMH rechargeable Battery*Power supply*: 110 - 240 V; 50/60 Hz(* optional Module required.May not be available in all regions)Region: USReproducibility: ± 0.005 Abs (0 - 1 A)Sample Cell Compatibility: 13 / 16 mm and 1 inch round adapter, 10 x 10 mm 1 inch square and 10x10mmStorage conditions: -30 to 60 °C (-22 to 140 °F), max. 80 % relative humidity (non-condensing)Stray Light: < 0.5 %T at 340 nm with NaNO2Temperature Range: 0 - 50 °C (32 - 122 °F)User Interface Languages: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech,Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian,Russian, Slovenian, Swedish, TurkishUser Programs: 50Wavelength Accuracy: ± 2 nm (range 340 - 800nm)Wavelength Calibration: AutomaticWavelength Range: 340 - 800 nmWavelength Reproducibility: ± 0.1 nmWavelength Selection: AutomaticWeight: 1.5 kgWhat's included?: Includes: basic printed instrument manual, dust cover, 1-in. square matched glass sample cells, AA alkaline batteries 4/pk, and a four-type adapter set.