Description
Calibration Points: 2 to 4, 2 to 5
Unit Size: Each
Features
• Durable waterproof and dustproof design with IP67 rating
• Large, backlit display – Viewmeasurement with temperature and % slope
• Grip-Clip™ – Quickly and easily secures the pH electrode to your beaker or container
• Calibrate up to 5 points automatically with USA or NIST buffer groups (up to 6 points with DIN). Newmanual option allows calibration with up to 5 custom buffer standards
• Auto buffer recognition – Automatically identifies the correct pH buffer for rapid calibration
• Calibration due alarm – Set a visible reminder when it is time to recalibrate themeter
• Ready indicator,manual or automaticmeasurement hold feature and optional automatic shutoff function
• Selectable °C/°F – Choose units to best fit your application
• Intuitive, user-friendly icons – Electrode status displays pH slope
• Store up to 500 data sets – Easy USB or RS232 output with optional data cables
• Built-in real-time clock stamps stored data and calibration data with time and date –meets standards for GLP (Good Laboratory Practices)
• Extended battery life from two AA batteries, or use optional universal power adapter
• Built-in stand with wall-mount option – Allows for easy benchtopmeasurement or storage
• Compatible with pH, ORP or ISE electrodes having a BNC connector Specifications Product Specification: Description pH
• Range: -2.00 to 16.00 pH
• Resolution: 0.01 pH
• Accuracy: ±0.01 pH
• Calibration: Up to 5 points (USA & NIST & CUSTOm), Up to 6 points (DIN) mV
• Range: ±2000mV
• Resolution: 0.1mV ±999.9mV; 1mV beyond
• Accuracy: ±0.2mV +2 LSD or +0.5 % of reading; whichever is greater
• Calibration: ±200mV ION
• Range: 0.0 to 2000 ppm
• Resolution: 0.01 / 0.1 / 1 ppm
• Accuracy: ±0.5 % full scale (monovalent); ±1 % full scale (divalent)
• Calibration: From 2-4 or 2-5 points: 0.10, 1.00, 10.0, 100.0 & 1000 / 0.20, 2.00, 20.0, 200.0 & 2000 / 0.50, 5.00, 50.0 & 500.0 Temperature
• Range: -10.0 to 110.0 °C (14.0 to 230.0 °F)
• Resolution: 0.1 °C/°F
• Accuracy: ±0.5 °C; ±0.9 °F
• Calibration: Offset in 0.1 increments, ±10 °C or ±18 °F Others
• Display: Custom LCD with backlight
• memory: Stores up to 500 data sets
• Output: USB or RS232
• Real-Time Clock: Time and date stamp on calibration and stored data
• Temperature Compensation: Automatic ormanual from -10 to 110 °C
• Power: Two AA batteries (included), >500 hours (without backlight); AC adapter (optional)
• Dimensions (L x W x H):meter: 7 7/8 x 3 1/8 x 2 1/4 in. (20 x 8.3 x 5.7 cm), Boxed: 9 1/8 x 9 1/8 x 2 3/4 in. (23 x 23 x 7 cm)
• Weight:meter: 1 lb (0.5 kg), Boxed: 1.4 lb (0.7 kg)