Description
Unit Size: Each
Fluke 414D/62MAX+ 414d Laser Distance Meter and 62 Max Ir Thermometer Key features The 414D reduces errors, saves time and money • The most advanced laser technology for distance measurement • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in) • Quick calculation of area (square feet/meters) and volume • Pythagoras function indirectly measures height via two other measurements • Stores up to five measurement results • Battery life of 3000 measurements with automatic shut-off feature Fluke 62 MAX+. Small in size. Big on toughness • Dust and water-resistant: IP54 rated • Rugged: 3-meter (9.8-foot) drop tested • Ergonomically designed: Completely redesigned for a more natural hand fit • Distance to spot: 12:1 • Dual lasers: Identifies area to be measured • Large, backlit display: Makes data easier to read, even in dark areas The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/hvac problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration. Fluke 414D Laser Distance Meter Distance Measurement Typical Measuring Tolerance ¹: ±2.0 mm ³ Maximum Measuring Tolerance ²: ±3.0 mm ³ Range At Leica Target Plate GZM26: 50 m / 165 ft Typical Range ¹: 40 m / 130 ft Range At Unfavorable Condition 4: 35 m / 115 ft Smallest Unit Displayed: 1 mm / 1/16 in Ø Laser Point At Distances: 6 / 30 / 60 mm (10 / 50 / 100 m) Tilt Measurement Measuring Tolerance To Laser Beam 5: No Measuring Tolerance To Housing 5: No Range: No General Laser Class: 2 Laser Type: 635 nm, < 1 mW Protection Class IP40 Automatic Laser Off: After 90 seconds Automatic Power Off: After 180 seconds Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03: Up to 3,000 measurements Size (L x W x D): 116 x 53 x 33 mm Weight (with batteries): 113 g Temperature Range:-25 °C to +70 °C (-13 °F to +158 °F) Storage Operation: 0 °C to +40 °C (32 °F to +104 °F) Calibration Cycle: Not applicable Maximum Altitude: 3000 m Maximum Relative Humidity: 85% at 20 °F to 120 °F (-7 °C to 50 °C) Fluke 62 MAX+ Infrared Thermometer Specifications Temperature Range: -30 °C to 650 °C (-22 °F to 1202 °F) Accuracy: ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 Response Time (95%): Fluke 62 MAX+ < 300 ms (95% of reading) Spectral response 8 to 14 microns Emissivity 0.10 to 1.00 Optical Resolution: 12:1 (calculated at 90% energy) Display Resolution: 0.1 °C (0.2 °F) Repeatability Of Readings: ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater Power: AA battery Battery Life 8 hours with laser and backlight on