Description
Unit Size: Each
FLUKE-54-2-B 50HZ Dual Input Thermometer W/recording (intl) Key features • Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG • Recall function allows logged data to be easily reviewed on the meter display • Infrared USB communication port allows data to be exported to optional FlukeView Forms; Temperature PC software for further analysis and graphing • Data Logging up to 500 points of data with user adjustable recording interval • Relative time clock on MIN, MAX, and AVG provides a time reference for major events • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy • Measures J, K, T, E, R, S, and N-type thermocouples • Readout in °C, °F, or Kelvin (K) • Splash and dust resistant case protected by impact absorbing holster • User-friendly front panel is easy to set up and operate • Sleep mode increases battery life; typical 1000-hour battery life • Battery door allows easy battery replacement without breaking the calibration seal • Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation • 3 years warranty Laboratory accuracy. Wherever you go Fluke 54 II B dual input digital thermometer can log up to 500 points of data to internal memory. Fast response and laboratory accuracy (0.05% + 0.3 °C). Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors). Specifications Temperature accuracy: Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C]¹ R and S-type: ±[0.05% + 0.4°C]1 Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C]¹ T-type: ±[0.50% + 0.3°C] Temperature: J-type -210°C to 1200°C K-type -200°C to 1372°C T-type -250°C to 400°C E-type -150°C to 1000°C N-type -200°C to 1300°C¹ R and S-type 0°C to 1767°C¹ Temperature scale: ITS-90 Applicable standards: NIST-175 Display resolution: 0.1°C, 0.1 K < 1000 1°C, 1 K ≥ 1000 1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples. Environmental Specifications Operating temperature: -10°C to 50°C Storage temperature: -40°C to 60°C Humidity (without condensation): 0% to 90%; 0°C to 35°C 0% to 70%; 0°C to 50°C Safety Specifications Overvoltage category: CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 Agency approvals: CE, CSA, TÜV (pending) Mechanical and General Specifications Size (L x W x D): 173 x 86 x 38 mm Weight: 400 g Batteries: 3 AA batteries; typical 1000-hour life Includes: • Impact absorbing holster • One 80PK-1 bead probe thermocouple