Description
Pressure Range: 100 psi
Unit Size: Each
Key features • ATEX II 1G Ex ia IIC T4 Compliant. • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve. • 30, 100, and 300 psi ranges (2, 7, and 20 bar) • Pressure measurement to 0.05% of full span, using an internal pressure sensor. • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules. • Wide range of selectable measurement units for pressure. • Current measurement with 0.02% accuracy and 0.001 mA resolution. • Pressure switch test function. • Min-Max Hold functions. • Compact size and weight. • Simple, push-button user interface. • Rugged and reliable, ideal for field use. Pump Up the Pressure The Fluke 718Ex Intrinsically Safe Pressure Calibrator is a powerful intrinsically safe, self contained pressure calibrator for usage in explosion endangered areas. Specifications Pressure Measurement Accuracy Range: -830 mbar to 2 bar (internal sensor) Over pressure: 2x FS Resolution: 0.001 bar Accuracy: 0.05% FS Functions: Zero, Min, Max, Hold, Damp For use with non-corrosive gasses. Supported Pressure Units psi, inH2O (4°C), inH2O (20°C), kPa, cmH2O (4°C), cmH2O (20°C), bar, mbar, kg/cm^2, mmHg, inHg Media compatibility per pressure module specs Technical Data Measure accuracy: Range 0-24 mA Resolution 0.001 mA Accuracy 0.02% rdg ±2 counts Display: LCD, 5 digit pressure and current simultaneous Environmental Specifications Operating temperature: -10°C to 55°C Storage temperature: -40°C to 60°C Humidity (without condensation): 95% (10°C to 30°C) 75% (30°C to 40°C) 45% (40°C to 50°C) 35% (50°C to 55°C) Operating altitude 3,000 m max Safety Specifications Safety ATEX II 1G Ex ia IIC T4 compliant CSA Certification I.S. Class I Div 1 Groups A-D , T4 Mechanical and General Specifications Size (L x W x H): 216 x 94 x 66 mm (with holster) Weight: Approx. 992 g (with holster) Warranty: Three years, one year for pump Shock: 1 meter drop test Vibration: Random, 2 G, 5-500 Hz Battery type: One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V Battery life: 4 to 20 hours, depending on functions used Model: FLUKE-718 EX100 Fluke 718Ex 100G Intrinsically Safe Pressure Calibrator 100 psi Includes: • Protective red holster • TL75 test leads • AC72 test clips • CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese) • Fluke 718Ex CCD content control drawing • NIST- traceable calibration report and data