Waters is phasing out Certificate of Analysis (COAs) for eCords. All column documents are now available at www.waters.com/coa
| Chemistry | C18 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Hybrid |
| pH Range Min | 1 pH |
| pH Range Max | 12 pH |
| Endcapped | Yes |
| Silanol Activity | Low |
| Molecular Weight Range Min | 1000 |
| Molecular Weight Range Max | 30000 |
| Particle Shape | Spherical |
| Particle Size | 1.7 µm |
| Endfitting Type | Parker-style |
| Pore Size | 300 Å |
| QC Tested | Peptide |
| Format | Column |
| System | UPLC, UHPLC |
| Particle Technology | BEH |
| USP Classification | L1 |
| Inner Diameter | 2.1 mm |
| Length | 150 mm |
| Carbon Load | 18 % |
| UNSPSC | 41115709 |
| Application | Peptide |
| Brand | ACQUITY UPLC |
| Product Type | Columns |
| Units per Package | 1 pk |
Answer:1.7 µm BEH particles with 300 Å pores.
Answer:Peptides in an approximate 1,000–30,000 Da molecular-weight range.
Answer:2.1 mm inner diameter × 150 mm length, one column per pack.
The Waters ACQUITY UPLC Peptide BEH C18 column is designed for high-efficiency reversed-phase separation of peptides in proteomics and protein characterization workflows. Its 300 Å wide-pore bridged ethyl hybrid particles provide access for larger peptide analytes, while the 1.7 µm particle size enables high-resolution separations with suitable UHPLC equipment. The analytical bed is 2.1 mm in inner diameter and 150 mm long, with a peptide-oriented molecular-weight range of approximately 1,000–30,000 Da. This column supports peptide mapping, characterization of digestion products and analysis of synthetic peptide mixtures. Gradient elution with water and organic mobile phases is commonly used to distribute peptides by hydrophobicity. Select injection load, gradient slope and mobile-phase additives to maintain peak shape and mass spectrometry compatibility where required. Verify instrument pressure capability and low-dispersion plumbing before using a long, sub-2-µm column. It is not an intact-protein size-exclusion column; the product is supplied as one UPLC peptide C18 analytical column.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.