| Chemistry | C18 |
|---|---|
| Separation Mode | Reversed Phase |
| Particle Substrate | Hybrid |
| pH Range Min | 1 pH |
| pH Range Max | 11 pH |
| Maximum Pressure | 18000 psi (1240 Bar) |
| Endcapped | Yes |
| Silanol Activity | Low |
| Molecular Weight Range Min | 1000 |
| Molecular Weight Range Max | 15000 |
| Particle Shape | Spherical |
| Particle Size | 1.7 µm |
| Endfitting Type | Direct-Connect |
| Pore Size | 130 Å |
| QC Tested | Peptide |
| Format | VanGuard Pre-column |
| Surface Area | 185 |
| System | UPLC, UHPLC |
| Particle Technology | CSH |
| USP Classification | L1 |
| Inner Diameter | 2.1 mm |
| Length | 5 mm |
| Carbon Load | 15 % |
| UNSPSC | 41115709 |
| Application | Peptide |
| Brand | ACQUITY UPLC |
| Product Type | Guards |
| Units per Package | 3 pk |
Answer:It is a 2.1 × 5 mm guard installed upstream of a compatible full-length peptide analytical column.
Answer:Three direct-connect VanGuard peptide pre-columns are supplied per pack.
Answer:The pre-column uses 1.7 µm, 130 Å charged-surface hybrid (CSH) C18 particles for matched peptide selectivity.
The Waters ACQUITY UPLC Peptide CSH C18 VanGuard pre-column protects a compatible analytical peptide column by intercepting particulates and strongly retained sample impurities before they reach the main separation bed. Each pre-column uses 1.7 µm charged-surface hybrid C18 particles with 130 Å pores in a short 2.1 × 5 mm format, and three pre-columns are supplied per pack. The CSH bonded phase matches the selectivity family of ACQUITY UPLC Peptide CSH C18 analytical columns designed for peptides in the approximate 1–15 kDa range. A direct-connect VanGuard design minimizes additional fluid connections and extra-column volume when installed on a compatible analytical-column inlet. Inspect the pre-column and mating fitting for cleanliness and correct seating before pressure is applied. Monitor backpressure and peptide peak shape during routine analysis; a blocked or exhausted guard should be replaced without assuming the analytical column itself is damaged. The pre-column is not a stand-alone replacement for the 150 mm analytical column.
Unless otherwise stated, the minimum order amount is USD 1,000.
For orders below USD 1,000, an additional handling fee may apply, or we may arrange local delivery / local handover where available.
All quotations are subject to final confirmation, including product availability, lead time, batch information, shipping cost, and applicable export or handling requirements.
For quotation requests, please send an RFQ from website or contact:
Please send inquiries directly to us in the “To” field. Emails sent via BCC, mass mailing, or with unrelated recipients may be automatically filtered and will not be processed.